INSTALLATION

INSTALLATION

HOW TO INSTALL YOUR OUTDOOR REFRIGERATOR/BEER DISPENSER

ELECTRICAL CONNECTION:

Check serial plate for correct power supply. Use only electrical power supply as specified on your appliance serial nameplate. Do not use an extension cord!

HOW TO INSTALL YOUR OUTDOOR REFRIGERATOR/BEER DISPENSER WARNING!

Do not splash or spray water from a hose onto the refrigerator! Doing so may cause an electrical shock, which may result in severe injury or death.

GROUNDING METHOD

This product is factory equipped with a power supply cord that has a three-pronged grounded plug. It must be plugged into a mating grounding type receptacle in accordance with the National Electrical Code and applicable local codes and ordinances. If the circuit does not have a grounding type receptacle, it is the responsibility and obligation of the customer to exchange the existing receptacle in accordance with the National Electrical Code and applicable local codes and ordinances. The third ground prong should not, under any circumstances, be cut or removed. All UL listed refrigerated products are equipped with this type of plug.

A ground fault circuit interrupter (GFI) electrical receptacle is to be used to supply electrical power to the refrig- erator for outdoor applications. Contact an electrician if you need to install one to supply electrical power to your outdoor refrigerator.

POWER REQUIREMENTS:

120V 60Hz

1800 watt

3 wire outlet

15 amp circuit

AC Interface

 

 

 

Power Supply Cord

 

 

 

 

with 3-Prong

 

 

 

 

Grounding

 

 

 

 

Plug

 

 

 

 

 

Grounding Type

Wall Receptacle

Note:

The plug shown is for 120V units.

Fig. 02

Fig. 03

5

Page 7
Image 7
Fisher & Paykel RF24R, RF24T Installation, How To Install Your Outdoor Refrigerator/Beer Dispenser, Electrical Connection