APPENDIX
LAMP REPLACEMENT
When the life of the Lamp of this projector draws to an end, the LAMP REPLACEMENT Indicator lights yellow. When the image becomes dark or the color of the image becomes unnatural, replacement of the Lamp is required.
CAUTION
● For continued safety, replace with a lamp assembly of the same type.
●Allow projector to cool for at least 45 minutes before you open the lamp cover. The inside of projector can become very hot.
●Do not drop the lamp assembly or touch the glass bulb! The glass can shatter and may cause injury.
Follow these steps to replace the lamp assembly.
1 | Turn off projector and disconnect AC plug. Allow projector to |
|
| cool for at least 45 minutes. |
|
2 | Remove a screw with a screwdriver and remove Lamp Cover. |
|
3 | Remove 2 screws and pull out Lamp Assembly by grasping |
|
| Handle. |
|
4 | Replace Lamp Assembly with a new one and tighten 2 screws. | LAMP COVER |
| Make sure that Lamp Assembly is set properly. Replace Lamp |
|
Cover and tighten a screw.
LAMP ASSEMBLY
5
6
Connect AC Power Cord to projector and turn on projector.
Reset Lamp Replace Counter (refer to the section “Lamp Replace Counter” below).
NOTE : Do not reset Lamp Replace Counter when Projection
Lamp is not replaced.
HANDLE
ORDER REPLACEMENT LAMP
Replacement Lamp can be ordered through your dealer. When ordering the Lamp, give the following information to the dealer.
● Model No. of your projector :
●Replacement Lamp Type No. :
(Service Parts No. 610 285 4824)
LAMP REPLACE COUNTER
Be sure to reset Lamp Replace Counter when Lamp Assembly is replaced. When Lamp Replace Counter is reset, LAMP REPLACE Indicator stops lighting.
1 | Turn projector on, press MENU button and |
| move a red frame pointer to SETTING Menu icon (refer to page 36, 37). |
2 | Press POINT DOWN button to move a red frame pointer to “Lamp counter reset” and then press SELECT button. The |
| message "Lamp replace counter reset?" is displayed. Move the pointer to [Yes] and then press SELECT button. |
3 | Another confirmation dialog box appears and select [Yes] to reset Lamp Replace Counter. |
Do not reset Lamp Replace Counter except after Projection Lamp is replaced.
39