ALARM RECORDING
Alarm Recording Counter Display
œDuring alarm recording, “AL” will be flashing on the digital display.
œIf the ON SCREEN switch is set to the “ON” position, the number of alarms will flash on the monitor screen.
œThe maximum display number of alarm recordings is “999”, at the next alarm recording the counter will indicate “000”.
œWhen the (ALARM TIME) menu is displayed, press the MENU RESET button to reset the alarm counter to “000” (all the data of the (ALARM TIME) menu is reset).
Connections to the ALARM IN/OUT Terminals
œAlarm input signal
Connect a
œAlarm output signal
Normally DC 5V are output between the ALARM OUT and the COM terminals. When an alarm input (trigger) is received and the unit is recording, the output falls to 0V. Once the alarm recording is over, the output returns to DC 5V.
Checking the Alarm Recordings Time
1Press the MENU button until the (ALARM TIME) menu is displayed.
øThe number of alarm recordings, and the 8 most recent alarm recording times are displayed.
@@@@@@<ALARM@TIME>
NOTE:
œThe data for the previous alarm recordings is erased.
2Press the SEARCH button, the normal screen is displayed.
NOTE:
œIf the MENU RESET button is pressed while the (ALARM TIME) menu is displayed, the displayed data is erased. “AL” will be erased from the digital display.
18 | English |