OUTPUT TERMINALS

SW OUT Terminal

When recording, a pulse signal is output at the SW OUT terminal.

This terminal is usually connected to the switch input (SW IN) of devices like a camera switcher unit, or a quad compressor.

FIELD: 16.7 msec.

FRAME: 5 msec.

5V (H)

(Output impedance: 5.7 kΩ) 0V (L)

SW OUT Terminal Output Setting

1Press the MENU button until the (SET UP 4) menu is displayed.

øThe FIELD (or FRAME) setting is flashing.

@@@@@@@<SET@UP@4>

öSW@OUT

@@FIELD@@@@@@@@@01

@@TIMING@@@@@@@@FIELD

@@8H@@@@@@@@@@@@Y

öTHREAD@CHECK@@@Y

öVIDEO@LOSS@@@@@N

öREC@SPEED@@@@@@N

öEJECT@SET

@@EJECT@MODE@@@@EJECT1

@@OPERATION@@@@@SLAVE

NOTE:

œIf “TIMING” is set to FRAME (see step 4), “FRAME” will be indicated instead of “FIELD”.

2Turn the SHUTTLE ring, to set the desired pulse signal interval.

Available settings are:

FIELD. . . . . . 01, 02, 03, 04, 05, 10, 30 or 60 field

FRAME . . . . 01, 02, 03, 04, 05, 10, 30 or 60 frame

3Turn the JOG dial clockwise until the “TIMING” setting is flashing.

4Turn the SHUTTLE ring, to set “FIELD” or “FRAME”.

FIELD. . . . . . 1 pulse is output after each set number of fields.

FRAME . . . . 1 pulse is output after each set number of frames.

5Turn the JOG dial clockwise until the “8H” setting is flashing.

NOTE:

œIf the TAPE SELECT switch to the “T-120”, “6H” will be indicated instead of “8H”.

6Turn the SHUTTLE ring, to set the desired “8H” mode.

Y. . . . . . . . . . When recording in 8-hour mode, a pulse signal is output.

N. . . . . . . . . When recording in 8-hour mode, a pulse signal is not output.

7Press the SEARCH button to save the settings.

SERIES OUT/NON REC OUT terminal setting

The output at the SERIES OUT/NON REC OUT terminal can be set.

1Press the MENU button until the (SET UP 1) menu is displayed.

@@@@@@@<SET@UP@1>

öDAYLIGHT@SET@@@@@USE

@@@@@@@@WEEK@MONTH@TIME

@ON@@@1ST-SUN@@04@02:00 @OFF@@LST-SUN@@10@02:00 öOUTPUT@@@@@@@@SERIES öCLOCK@SET @10-15-99@FRI@@15:20:00 öREMOTE@@@@@@@@EJECT öLANGUAGE-LANGUE-IDIOMA

@@@ENGLISH

2Turn the JOG dial, until the “OUTPUT” setting is flashing.

3Turn the SHUTTLE ring, to select the desired output mode.

SERIES . . . . If during series recording, the counter reading reaches

7H57M00S or the tape reaches the end, a LOW signal (0 V) is output. The LOW (0 V) signal is output for about 70 seconds after the end of the tape is reached.

NON REC . . If during recording the VCR enters a mode other than recording (i.e. recording pause, stop mode, etc.), a LOW signal (0 V) is output. If recording is resumed, then a HIGH signal (5 V) is output.

If in the (SET UP 2) menu, in the BUZZER section, WARNING is set to “Y”, a buzzer will be heard while the VCR is in non recording mode. The buzzer will stop if the STOP button is pressed (the output signal will remain LOW (0 V)).

4Press the SEARCH button to save the setting.

36