Fluke 960PS-210 manual Introduction, Section, General Description, Application, Specifications

Models: 960PS-210 960PS-200

1 16
Download 16 pages 48.24 Kb
Page 5
Image 5
General Description 1

Introduction

General Description 1

Section 1

Introduction

1.1 General Description

The 960PS Power Supply is used to supply power to the modules that are plugged into the 960MB/961MB motherboards.

The power supply is mounted outside of the 960CC Card Cage Module, the wall mounted Local Control Unit enclosure, or control room cabinet. The input AC voltage is soft started to inhibit current surges when powered up. EMI protection is also provided as part of the AC voltage protection. The power supply has remote error sensing and short circuit/overload protection along with input and output over-voltage protection. See Figure 1-1, the Power Supply Functional Block Diagram.

1.2 Application

The 960PS-200 & 960PS-210 Power Supply Modules are used in VICTOREEN series area monitors, process monitors, isolators, control rooms, and safety-related display cabinets.

1.3 Specifications

General specifications for the power supply are listed below.

 

960PS-200
960PS-210

Dimensions (W x H x D)

4.2 x 2.25 x 6.66 in

5.0 x 2.5 x 10.5 in

Operating Temperature

0° to 50°C, Full Rated

0° to 50°C, Full Rated

Relative Humidity

95% Non-Condensing

95% Non-Condensing

Input Voltage

115 VAC ± 15%

90 - 132 VAC/180 - 240 VAC

 

(jumper

 

60 Hz ± 5%

selectable) 47 - 440 Hz

Input Power

155 watts

130 watts

Efficiency

71%

75% Minimum

Input Filtering

Common Mode

Common Mode and Differential

Mode

 

 

Output Voltages

+5 VDC ± 0.2% @ 10 Amps

+5 VDC ± 0.2% @ 15 Amps

 

+15 VDC ± 5% @ 2 Amps

(10% load required for regulation)

 

-15 VDC ± 5% @ 2 Amps

+15 VDC ± 2% @ 3 Amps

 

 

-15 VDC ± 2% @ 2 Amps

 

 

+24 VDC ± 1.5% @ 2 Amps

Remote Error Sensing

+5 VDC Sense Provided

+5 VDC Sense Provided

Fault Protection

Short circuit protected by current

Short circuit protected by current

 

foldback with automatic recovery

foldback with automatic recovery

Line Voltage Monitor

Not Provided

Factory Set to 90 VAC

1-1