FMI FVF24PW To Turn Off Gas To Appliance, Manual Lighting Procedure, Optional Remote Operation

Models: FVF18PW FVF30PW FVF24PW

1 24
Download 24 pages 38.21 Kb
Page 15
Image 15
TO TURN OFF GAS

OWNER’S MANUAL

OPERATING

HEATER

Continued

9.Slightly push in and turn control

knob counterclockwise Shutting Off Heater to the ON position.

10.Wait one minute and switch selector switch to the ON position to light burner. Note:AUTO is only functional when using GWMT1 or GWMS2 op- tional accessories.

11.Set flame adjustment knob to any level between HI and LO.

Shutting Off Burner Only (pilot stays lit) CAUTION: Do not try to adjust heating levels by using the equip- ment shutoff valve.

MANUAL LIGHTING WARNING: Make sure the selector switch is in the OFF po- sition when you are away from home for long periods of time. Heater will come on automati- cally with selector switch in the ON position.

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1.Turn control knob clockwise ing Instructions, page 14. to the OFF position.

2a. Set selector switch in the OFF position.

2b. If Using Optional Hand-Held Re- mote: Set selector switch in the OFF position to keep from draining battery.

Shutting Off Burner Only (pilot stays lit)

You may shut off the burner and keep the pilot lit by doing one of the following:

1.Turn control knob clockwise OPTIONAL REMOTE to the PILOT position.

2.Use remote control manual OFF button.

3.Set selector switch in the OFF position.

MANUAL LIGHTING

PROCEDURE

1.

Follow steps 1 through 6 under Light-

 

ing Instructions, page 14.

2.

Depress control knob and light pilot

 

with match.

OPTIONAL REMOTE

OPERATION

Note: All remote control accessories must be purchased separately (see Accessories, page 21). Follow instructions included with the remote control.

Thermostat Control Operation

(Optional GHRCTA Series Only) The thermostat control setting on the remote control unit can be set to any comfort level between WARMER and COOLER. The burners will turn on and off auto- matically to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.

For wall thermostat operation, follow in- struction supplied with thermostat acces- sory GWMT1. For wall switch operation follow instructions supplied with GWMS2.

NOTICE: You must light the pilot before using the hand-held re- mote control unit. See Lighting Instructions on page 14.

Pilot Burner

Figure 21- Pilot

Ignitor Electrode

3. Keep control knob pressed in for 30

seconds after lighting pilot. After 30

seconds, release control knob. Now

follow steps 9 through 11, column 1.

1.After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Adjust flame adjust- ment knob anywhere between HI and LO. Slide the selector switch to the REMOTE position (see Figure 22). Note: The burner may light if hand-held remote ON button was on when selector switch was last turned off. You can now turn the burner on and off with the hand-held remote control unit.

IMPORTANT: Do not leave the se- lector switch in the REMOTE posi- tion when the pilot is not lit. This will drain the battery.

IMPORTANT: Be sure to press the ON/OFF buttons on the hand-held remote control unit for up to 3 sec- onds to assure proper operation.

GHRC Series Operation:

2a. Press the ON/OFF button to turn the burner on and off. When turning burner off, the pilot will remain lit.

Continued

105194

15

Page 15
Image 15
FMI FVF24PW To Turn Off Gas To Appliance, Manual Lighting Procedure, Optional Remote Operation, Shutting Off Heater