FMI FVF18PW Inspecting Burners, Pilot Flame Pattern, Burner Primary Air Holes, Main Burner

Models: FVF18PW FVF30PW FVF24PW

1 24
Download 24 pages 38.21 Kb
Page 16
Image 16
GHRCTA Series Operation:

FIREPLACE MANUFACTURERS INCORPORATED

UNVENTED PROPANE/LP GAS LOG HEATER

OPERATING

HEATER

Continued

GHRCTA Series Operation:

2b. Press the AUTO/ON/OFF button on the hand-held remote control (see Figure 22, page 17). The lights to the left of the button will show AUTO, ON, or OFF.

In the ON mode, the burners will ignite. The heater is in manual mode when ON is lit.

In the AUTO mode, the thermostat in the hand-held remote unit con- trols the room temperature. To in- crease the room temperature, press the top arrow of the TEMP button. To lower the room temperature, press the bottom arrow of the TEMP button. At higher settings the heater will run longer.

IMPORTANT: This remote control has been specially engineered to take an air temperature sample ev- ery 5.5 minutes in the auto mode. It will not respond immediately to the temperature setting being turned up or down.

IMPORTANT: The hand-held re- mote control unit must be near the heater. Do not keep the hand-held remote control unit too close to the heater. The thermostat on the hand-held remote control unit will heat up too quickly and turn the heater off.

3.To turn the burner off, press the AUTO/ON/OFF button until OFF lights. The pilot will remain lit.

IMPORTANT: To turn the pilot off, manually turn the control knob on the heater to the OFF position.

INSPECTING

BURNERS

Check pilot flame pattern and burner flame patterns often.

PILOT FLAME PATTERN

Figure 24 shows a correct pilot flame pat- tern. Figure 25 shows an incorrect pilot flame pattern. The incorrect pilot flame is not properly heating the thermocouple. When the thermocouple cools, the heater will shut down.

If pilot flame pattern is incorrect, as shown in Figure 25

turn heater off (see To Turn Off Gas to Appliance, page 15)

see Troubleshooting, pages 17 through 19

Pilot Burner

Thermocouple

 

Control Knob in

Flame Adjustment Knob

On Position

IH

 

F

PIL

ON

 

O

 

O

 

T

OFF

 

O

 

 

 

 

N

REMOTE

 

 

 

 

 

LO

 

 

 

Selector Switch in Remote Position (Optional

Remote Control)

Figure 22 - Setting the Selector Switch, Control Knob, and Flame Adjustment Knob for Remote Operation

Figure 24 - Correct Pilot Flame Pattern

Pilot Burner

Thermocouple

Figure 25 - Incorrect Pilot Flame Pattern

Shows Temperature Setting

The Log Heater will Automatically Cycle between Pilot and the Heat Setting that has been Selected

Increases Room

Temperature in

AUTO Mode

Decreases Room

Temperature in

AUTO Mode

Turns Burners On or Off and Allows You to Choose the Auto Setting

BURNER PRIMARY AIR HOLES

Air is drawn into the burner through the holes in the fitting at the burner entrance. These holes may become blocked with dust or lint. Periodically inspect these holes for any blockage and clean if needed. Blocked air holes will create soot.

MAIN BURNER

Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame

Figure 23 - Thermostat Hand-Held Remote Control Unit Selections (GHRCTA Series Only)

present. Some burner flame holes may be- come blocked by debris or rust, with no flame present. If so, turn off heater and let cool. Remove blockage. Blocked burner flame holes will create soot.

16

105194

Page 16
Image 16
FMI FVF18PW Inspecting Burners, Pilot Flame Pattern, Burner Primary Air Holes, Main Burner, GHRCTA Series Operation