SPECIFICATIONS

OWNER’S MANUAL

SPECIFICATIONS

 

18" Variable

24" Variable

30" Variable

Btu (Variable)

16,000/26,000

20,000/33,000

21,5000/36,000

Type Gas

Propane/LP Only

Propane/LP Only

Propane/LP Only

Ignition

Piezo

Piezo

Piezo

Manifold Pressure

7.9" W.C.

7.9" W.C.

7.9" W.C.

Inlet Gas Pressure

 

 

 

(in. of water)

 

 

 

Maximum

14"

14"

14"

Minimum*

11"

11"

11"

Shipping Weight

32 lbs.

34 lbs.

36 lbs.

* For purpose of input adjustment

WIRING DIAGRAM

OFF

ON

Thermopile

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call Fireplace Manufacturers Incorporated’s Technical Service Depart- ment at 1-888-427-8322.

When calling Fireplace Manufacturers In- corporated, have ready

your name and address

model and serial numbers of your heater

how heater was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the defec- tive part to the factory.

PARTS NOT UNDER

WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call Fireplace Manufacturers Incorporated’s Parts Department at 1-800- 888-2050 for referral information.

When calling Fireplace Manufacturers In- corporated, have ready

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burners will have delayed ignition

heater will not produce specified heat

propane/LP gas supply may be low

When Gas Quality Is Bad

pilot will not stay lit

burners will produce flames and soot

heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local propane/LP gas supplier.

TECHNICAL

SERVICE

You may have further questions about in- stallation, operation, or troubleshooting.

If so, contact DESA International’s Techni- cal Service Department at 1-800-DESA LOG (1-800-337-2564).

You can also visit DESA International’s technical services web site at www.desatech.com.

model and serial numbers of your heater