FortiGate-5001FA2-LENC Security System Guide
18 01-30000-76602-20080606
Troubleshooting Hardware installation
5Open the left and right handles to their fully open positions.
Opening the handles slides the board a short distance out of the slot,
disconnecting the board from the chassis backplane.
The IPM LED turns blue. All other LEDs turn off.
6Pull the board about half way out.
All LEDs turn off.
7Turn both handles to their fully-closed positions.
When the handles are fully-closed they lock into place.
8Carefully slide the board completely out of the slot.
Troubleshooting
This section describes the following troubleshooting topics:
FortiGate-5001FA2-LENC does not startup
FortiGate-5001FA2-LENC cannot display chassis information

FortiGate-5001FA2-LENC does not startup

Positioning of FortiGate-5001FA2-LENC handles, the presence or absence of a
functioning shelf manager, incorrect jumper settings and firmware problems may
all prevent a FortiGate-5001FA2-LENC board for starting up correctly. This section
describes how to find and fix each of these problems.

All chassis: left handle not contacting power switch

The left handle activates the FortiGate-5001FA2-LENC board power switch.
Open
Fully Open
Alignment Pin
Handle
Handle
Close Fully Closed
and Locked
Alignment Pin
Alignment Pin
Handle