Foster FCI30, F85, F20, F40, F60, FCI85 Maintenance and Cleaning Instructions, General, Icemaker

Models: FCI60 FCI30 FCI20 FCI40 FCI85 F60 F40 F20 F85

1 23
Download 23 pages 51.61 Kb
Page 22
Image 22

16.Maintenance and Cleaning Instructions

16.1 General

The periods and the procedures for maintenance and cleaning are given as guides and are not to be construed as absolute or invariable. Cleaning, especially, will vary depending upon local water and ambient conditions and the ice volume produced; and, each ice maker must be maintained individually, in accordance with its particular. location requirements.

16.2 Icemaker

The following maintenance should be scheduled at least twice per year on these ice makers.

1.Check and clean the water line strainer.

2.Check that the ice maker is levelled side to side and in front to rear directions.

3.Clean the water system, the evaporator, the bin and spray platen using a solution of Ice Machine Cleaner.

Refer to procedure 15.3 cleaning instructions and after cleaning will indicate frequency and procedure to be followed in local areas.

NOTE Cleaning requirements vary according to the local water conditions and individual user operation. Continuous check of the clarity of ice cubes and visual inspection of the water spraying parts before and after cleaning will indicate frequency and procedure to be followed in local areas.

4.With the ice machine and fan motor OFF on air cooled models, clean condenser using vacuum cleaner, soft brush or non metallic brush.

5.Check for water leaks and tighten drain line connections. Pour water down bin drain line to be sure that drain line is open and clear.

6.Check size, condition and texture of ice cubes. Perform adjustment of DIP SWITCH keys as required.

7.Check the ice level control sensor to test shut-off.

Put a shovelful of ice cubes in contact with the control sensor during the defrost cycle.

This should cause the ice maker to shut off at the end of the defrost cycle and the light up the 3rd RED LED.

Within a few seconds after the removal of the shovelful of ice from the sensing probe, the ice maker restarts in freezing cycle.

NOTE The RANGE OF THE ICE LEVEL CONTROL SENSOR can be adjusted as shown on table D of PRINCIPLE OF OPERATION; its cut out setting remains however at +2˚C (35˚F).

8.Check for refrigerant leaks.

16.3Cleaning Instructions of Water System

1.Remove the rear and top panels to gain access either to the control box or to the evaporator.

2.Wait till the end of defrost cycle then, with the help of a normal screwdriver, turn the program selector head on STAND BY position to temporarily stop the operation (Fig. 10). + (Fig. 8) (R134A Machines Fig. 7).

Fig. 10

3.Prepare the cleaning solution by diluting in a plastic container one or two litres of warm water (45-50˚C) with 0.1-0.2 litres of Ice Machine Cleaner.

WARNING The Ice Machine Cleaner contain: Phosphoric and Hydroxyacetic acids.

These compound: are corrosive and may cause bums if swallowed, DO NOT induce vomiting. Give large amount: of water or milk. Call Physician Immediately.

In case of external contact flush with water.

KEEP OUT OF THE REACH OF CHILDREN.

4.Scoop out all the ice cubes stored into the bin in order to prevent them from being contaminated with the cleaning solution then flush out

the

water from the sump reservoir by removing the plastic plug.

5.Remove the evaporator cover then slowly pour onto the evaporator platen the cleaning solution. With the help of a brush dissolve the most

resistant and remote scale deposits in the platen.

6.Set the program selector head on CLEANING/RINSING (Fig. 11) + (Fig. 9).

21

Page 22
Image 22
Foster FCI30, F85, F20, F40 Maintenance and Cleaning Instructions, General, Icemaker, Cleaning Instructions of Water System

FCI60, FCI30, FCI20, FCI40, FCI85 specifications

Foster F85, F20, F40, and F60 represent a remarkable lineup of industrial and commercial engines, celebrated for their reliability, efficiency, and advanced technology. These models cater to various applications, striking a balance between performance and economy.

The Foster F85 is designed for smaller machinery and equipment, perfect for light-duty tasks. It features a compact design that allows for easy installation in tight spaces. With a robust power output and energy-efficient operation, the F85 engine is coupled with advanced fuel injection technology that enhances performance and reduces emissions. Its low-maintenance requirements make it a favorite among operators looking for dependable machinery without extensive upkeep.

The Foster F20 escalates the performance, making it suitable for medium-duty applications. It boasts a higher torque output, allowing it to handle more demanding tasks while maintaining excellent fuel efficiency. The F20 integrates cutting-edge electronic control systems that optimize engine performance in real time. This model also features noise reduction technology, contributing to quieter operation in urban or sensitive environments.

Progressing to the Foster F40, this engine shines in heavy-duty applications, offering significant power and efficiency. With a robust design, the F40 is capable of withstanding harsh working conditions without compromising on performance. It features advanced thermal management systems that ensure optimal operating temperatures, enhancing engine lifespan and reliability. Moreover, the F40 incorporates modular components, promoting ease of repair and maintenance.

Lastly, the Foster F60 is the flagship model in this lineup and stands out for its exceptional power-to-weight ratio. It is engineered with the latest innovations in turbocharging, which provides increased horsepower while maintaining low fuel consumption. The F60 also integrates sophisticated diagnostic tools that help operators monitor performance and anticipate maintenance needs, thus minimizing downtime.

Across this range, Foster engines emphasize sustainability through reduced emissions and noise output, adhering to strict industry regulations. From the entry-level F85 to the high-performance F60, each model showcases Foster's commitment to engineering excellence and the evolving needs of industries. Whether for construction, agriculture, or commercial use, the Foster F series represents a wise investment for efficiency and reliability.