Ethernet Cables

When connecting an RJ-45/RJ-48 port to an end station, workstation or server, use a standard RJ-45/RJ-48 pin-out cable.

Console Interface

A simple menu-driven interface provides for system initialization and diagnostics. The Console interface is EIA232 VT-100 compatible. The primary purpose of the terminal interface is to set basic operational parameters.

The terminal interface is password protected. By default there is no password set for the terminal interface.

Using the enclosed serial cable (see table below for wiring), connect the RJ-45 connector to the connector marked “Console” and the other side to the 9-pin serial port connector on the back of your PC.

The supplied cable has the following pinout:

 

 

 

 

Switch Side

PC Side

 

 

 

 

 

 

 

 

 

 

 

 

RJ-45 Pin #

DB-9 Female

 

 

 

 

 

 

 

 

 

 

 

3

2

 

 

 

 

 

 

 

 

 

 

 

2

3

 

 

 

 

 

 

 

 

 

 

 

5

5

 

 

 

 

 

 

 

 

 

 

 

 

NOTE

You can also use a RJ-45/DB-9 cable.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DC Power installation

The DC supply source is to be located within the same premises as this equipment. The DC power source should be protected with a circuit breaker with a rating of 10Amp as disconnect device, connected to the non-grounding conductor. The unit shall be connected directly to the DC supply system; there shall be no switching or disconnecting devices in the earthed circuit conductor between the DC source and the point of connection of the grounding electrode conductor.

This equipment shall be located in the same immediate area (such as, adjacent cabinets) as any other equipment that has a connection between the earthed conductor of the same DC supply circuit and the grounding conductor, and also the point of grounding of the DC system. The DC system shall not be earthed elsewhere.

January 2007

© 2007 Foundry Networks, Inc.

15

Page 21
Image 21
Foundry Networks M2404C, M2404F manual Ethernet Cables, Console Interface, DC Power installation, Switch Side PC Side

M2404F, M2404C specifications

Foundry Networks, a key player in the networking industry, has developed a range of high-performance Ethernet switches designed to meet the demands of modern data centers and enterprise environments. Among these products, the M2404C and M2404F switches stand out for their robust features and capabilities.

The M2404C is engineered for flexibility and high performance, offering Layer 2 and Layer 3 capabilities. It supports a wide array of routing protocols, including OSPF, BGP, and RIP, making it suitable for various network architectures. The switch provides up to 48 Ethernet ports with a combination of Gigabit and 10 Gigabit interfaces, ensuring it can handle high bandwidth requirements. This modularity allows organizations to scale their networks seamlessly as their needs evolve.

On the other hand, the M2404F focuses on fiber connectivity and is designed with an emphasis on high-speed fiber handling. This switch also supports advanced Layer 3 routing capabilities, but its standout feature is its support for higher-speed interfaces, like 10 Gigabit SFP+ ports. It is ideal for businesses that require efficient long-distance data transmission and reliable network performance.

Both models feature Foundry's innovative Fabric Technology, which enhances throughput and reduces latency. This technology optimizes data flow and improves overall service quality, making these switches suitable for mission-critical applications. Additionally, they boast a comprehensive management system that simplifies network administration. Foundry Networks emphasizes security, incorporating advanced features like Access Control Lists (ACLs), RADIUS, and TACACS+ support to help secure the network infrastructure.

Scalability is another critical aspect of the M2404C and M2404F. These switches allow for stacking, enabling organizations to expand their network without sacrificing performance. Power over Ethernet (PoE) capabilities in the M2404C provide added convenience for powering devices like IP phones and wireless access points.

In summary, Foundry Networks' M2404C and M2404F switches deliver exceptional performance, advanced features, and robust security, making them an excellent choice for organizations seeking to enhance their networking infrastructure. With their modular design and ability to support high-speed connectivity, they are well-suited for a variety of applications, from enterprise environments to data center deployments.