Franke Consumer Products FNE 905 XS ECS manual Easy Cleaning TM, Removing the Grease Filters

Models: FNE 905 XS ECS

1 56
Download 56 pages 40.98 Kb
Page 10
Image 10

EASY CLEANING TM

Removing the Grease Filters

Before carrying out Maintenance on the EASY CLEANING Suction Unit:

• Disconnect the hood by switching off the

twopole switch on the mains power supply

A

line, or by switching off the main power

 

switch.

 

Remove the grease filters from the hood.

If the hood is of the recirculation type, re- move the odour filters:

For hoods with a flat cartridge (A): turn the

 

fastening elements provided;

B

For hoods with a bayonet cartridge (B):

 

 

turn as indicated and extract.

 

Disconnecting the EASY CLEANING Suction Unit

Disconnect the power connector Ca and the control and lighting connector Cmd on the sides of the unit.

For wall-mounted hoods and free-standing hoods with square chimney, turn the levers Lb locking the suction unit, so that they disconnect from the pins.

For free-standing hoods with round chim- ney, unscrew the plugs Vb locking the suc- tion unit.

Pull the suction unit forwards so that it un- hooks from the support pins, and remove it downwards through the air outlet.

Ca

Cmd

Lb

Vb

EN

 

1

 

10

Page 10
Image 10
Franke Consumer Products FNE 905 XS ECS manual Easy Cleaning TM, Removing the Grease Filters