Franke Consumer Products FPL 606 Grease filters, Activated charcoal filter Recirculation version

Models: FPL 906 FPL 606

1 48
Download 48 pages 27.78 Kb
Page 22
Image 22
Grease filters

Grease filters

CLEANING METAL SELF- SUPPORTING GREASE FILTERS

The filters must be cleaned every 2 months of operation, or more frequently for particularly heavy usage, and can be washed in a dishwasher.

Remove the filters one at a time by pushing them towards the back of the group and pulling down at the same time.

Wash the filters, taking care not to bend them. Allow them to dry before refitting.

When refitting the filters, make sure that the handle is visible on the outside.

Activated charcoal filter (Recirculation version)

These filters are not washable and cannot be regenerated, and

B

 

must be replaced approximately every 4 months of operation, or

A

more frequently with heavy usage.

 

 

REPLACING THE ACTIVATED CHARCOAL FILTER

Remove the metal grease filters

Remove the saturated activated charcoal filter as shown (A).

Fit the new filters (B).

Replace the metal grease filters.

Lighting

LIGHT REPLACEMENT

20 W halogen light.

• Remove the snap-on lamp cover by levering it from under the metal ring, supporting it with one hand.

Remove the halogen lamp from the lamp holder by pulling gently.

Replace the lamp with a new one of the same type, making sure that you insert the two pins properly into the housings on the lamp holder.

Replace the snap-on lamp cover.

EN

 

2

 

22

Page 22
Image 22
Franke Consumer Products FPL 606, FPL 906 manual Grease filters, Activated charcoal filter Recirculation version, Lighting