Component description / A-Series specifications
VERT-I-PAK SINGLE PACKAGED VERTICAL AIR CONDITIONERS
9,000 / 12,000 / 18,000 / 24 K BTUs/h
All units are factory assembled, piped, wired and fully charged with
The 9,12 and 18 K BTUs units are 23 1/8” wide x 23 1/8” deep x 32 1/4” high. The 24 K BTUs unit is 23 1/8“ wide by 23 1/8” deep x 47 1/4“ high. Units draw in ambient air through upper portion of an outside architectural louver measuring 25 9/16” wide x 31 1/16” high and shall exhaust heated air out through the lower portion of the louver. The unit is to be inserted to the architectural louver by means of a two part,
REFRIGERATION SYSTEM – The refrigeration system consists of a hermetically sealed rotary compressor that is externally mounted on vibration isolators; condenser and evaporator coils constructed of copper tubes and aluminum plate fins; and capillaries as expansion devices. The coils are of
INDOOR BLOWER / OUTDOOR FAN – The current
Different size (HP) motors and/or different diameter blower wheels are used in different models to obtain the required airflow.
CONTROLS – Are electronic and factory equipped with terminal strip for connection to a standard
GENERAL CONSTRUCTION – The unit is constructed of 18 gauge G90
The unit includes two vibration isolators mounted under the chassis and a
The unit has a plastic fan, fan shroud and drain pan for corrosion protection and to help prevent rust on the side of the building below the outdoor louver.
The unit is shipped with return air filter brackets and a 14" x 20" filter affixed directly on to the unit chassis. Other optional factory accessories are available for mounting the return air filter in the mechanical closet door or an access panel.
Optional return air grilles shall be available as factory accessories for installation in the wall or door of the mechanical closet.
19