ELECTRONIC CONTROL BOARD FEATURES
The new Friedrich
Below is a list of standard features on every Friedrich VPAK and their benefit to the owner.
Quiet Start/Stop | The fan start and stop delays prevent abrupt changes in room acoustics due to the compressor energizing | |
or stopping immediately. Upon call for cooling or heating the unit fan will run for five seconds prior to en- | ||
Fan Delay | ergizing the compressor. Also, the fan off delay allows for “free cooling” by utilizing the already cool indoor | |
| coil to its maximum capacity by running for 30 seconds after the compressor. | |
|
| |
Remote Thermostat | VPAK units are thermostat controlled. | |
Operation | ||
| ||
|
| |
Internal Diagnostic | The new Friedrich digital VPAK features a self diagnostic program that can alert maintenance to compo- | |
Program | nent failures or operating problems. The internal diagnostic program saves properties valuable time when | |
diagnosing running problems. | ||
|
| |
Service Error Code | The self diagnosis program will also store error codes in memory if certain conditions occur and correct | |
themselves such as extreme high or low operating conditions or activation of the room freeze protection | ||
Storage | feature. Storing error codes can help properties determine if the unit faced obscure conditions or if an error | |
| occurred and corrected itself. | |
|
| |
| When the VPAK senses that the indoor room temperature has fallen to 40°F the unit will cycle on high fan | |
Room Freeze | and the electric strip heat to raise the room temperature to 46°F then cycle off again. This feature works | |
Protection | regardless of the mode selected and can be turned off. The control will also store the Room Freeze cycle | |
in the service code memory for retrieval at a later date. This feature ensures that unoccupied rooms do not | ||
| reach freezing levels where damage can occur to plumbing and fixtures. | |
|
| |
Random | Multiple compressors starting at once can often cause electrical overloads and premature unit failure. | |
Compressor Restart | The random restart delay eliminates multiple units from starting at once following a power outage or initial | |
power up. The compressor delay will range from 180 to 240 seconds. | ||
|
| |
Digital Defrost | The new Friedrich VPAK uses a digital thermostat to accurately monitor the outdoor coil conditions to allow | |
Thermostat | the heat pump to run whenever conditions are correct. Running the VPAK in heat pump mode save energy | |
and reduces operating costs. The digital thermostat allows maximization of heat pump run time. | ||
|
| |
Instant Heat | Heat pump models will automatically run the electric heater during compressor | |
Heat Pump Mode | heat when initially energized, then return to heat pump mode. This ensures that the room is heated quickly | |
without the usual delay associated with heat pump units. | ||
|
| |
Emergency Heat | In the event of a compressor failure in heat pump mode the compressor may be locked out to provide heat | |
Override | through the resistance heater. This feature ensures that even in the unlikely event of a compressor failure | |
the room temperature can be maintained until the compressor can be serviced. | ||
|
| |
Desk Control Ready | All electronic VPAK units have low voltage terminals ready to connect a desk control energy management | |
system. Controlling the unit from a remote location like the front desk can reduce energy usage and | ||
| requires no additional accessories at the VPAK. | |
|
| |
Indoor Coil Frost | The frost sensor protects the compressor from damage in the event that airfl ow is reduced or low outdoor | |
temperatures cause the indoor coil to freeze. When the indoor coil reaches 30°F the compressor is | ||
Sensor | diabled and the fan continues to operate based on demand. Once the coil temperature returns to 45°F the | |
| compressor returns to operation. | |
|
| |
The VPAK series units feature a indoor fan system design that reduces sound levels without | ||
System | lowering airflow and preventing proper air circulation. | |
|
| |
High Efficiency | The VPAK benefits quality components and extensive development to ensure a quiet, efficient and | |
dependable unit. | ||
| ||
|
| |
Rotary Compressor | High efficiency rotary compressors are used on all Friedrich VPAKs to maximize durability and efficiency. | |
|
| |
Auxiliary Fan Ready | The VPAK features a 24V AC terminal for connection to an auxiliary fan that may be used to transfer air to | |
adjoining rooms. Auxiliary fans can provide conditioning to multiple rooms. | ||
| ||
|
|
13