Door Gasket

C24GA SERIES CONVECTION STEAMERS - REMOVALAND REPLACEMENT OF PARTS

Door Gasket

1.Open the door.

2.Remove screws from the gasket guard and gasket plate.

3.Remove the gasket guard and the gasket plate.

4.Position the new gasket on the gasket plate.

5.Reverse the procedure to install.

6.Adjust the door as outlined under SERVICE PROCEDURES AND ADJUSTMENTS.

Damage to the gasket sealing surface, such as nicks or cuts, will cause steam leakage.

Door Handle

1.Open the door.

2.Remove screws from the top and bottom of the door.

3.Pull the outer door panel out from the door housing.

4.Remove the plate, nuts, washers and spacers from the handle screws and remove the door handle from the door.

5.Reverse procedure to install. When installing the spacers, the smaller diameter fits into the slot in the door and the latch. Use Loctite 271 to secure fasteners.