COMPONENT FUNCTION

C24GA SERIES CONVECTION STEAMERS - ELECTRICAL OPERATION

COMPONENT FUNCTION

COOKING COMPARTMENT

General

The upper section of the steamer consists of two separate cooking compartments. Each compartment functions independently with its own set of controls. Power is supplied to the controls only after the steam pressure rises above 4 psi to energize the compartment latching relay. The relay remains energized as long as Main Power Switch is on.

Ready Light (Green)

When the Green Ready Light is lit, it indicates steamer is ready to cook.

Cooking Light (Red)

When the Red Cooking Light is lit, it indicates steamer is in a cooking cycle.

Cooking Timer

The Cooking Timer is used to set desired cooking cycle time between 0 – 60

 

minutes. When a timer is set, the steam supply solenoid valve is energized to

 

allow steam into the cooking compartment, but only after the generator has

 

reached its operating pressure. Also, the timer energizes the buzzer when time

 

expires. The timer can be set to the constant steam position. This allows

 

steam to flow into the cooking compartment continuously.

Power On/Off Switch

The Power On/Off Switch located on the lower compartment control panel,

 

supplies power to the controls when in the on position, and causes the steam

 

generating process to start in the generator.

Power Indicator Light

The Power Indicator Light, located to the left of the Power On/Off Switch, is

 

illuminated when the Power On/Off Switch is in the on position.

Buzzer

The Buzzer signals the end of a cook cycle and must be turned off manually.

Door Switch

The Door Switch removes electrical power to the timer.

Steam Solenoid Valve

The Steam Solenoid Valve is normally closed, and when energized, opens to

 

allow steam into the cooking compartment.

Steam Supply Header

The Steam Supply Header is the main steam supply line from the generator for

 

each cooking compartment. The header supplies steam up to the steam

 

solenoid valve.