2.Remove rear and side panels as outlined under

C24GA SERIES CONVECTION STEAMERS - REMOVALAND REPLACEMENT OF PARTS

1.Drain the generator and allow steamer to cool, if necessary.

2.Remove rear and side panels as outlined under

COVERS AND PANELS.

3.Disconnect gas line at gas combination control valve.

4.Disconnect wires to burner assembly.

5.Disconnect wires from gas combination control valve.

6.Remove the nuts securing the burner to generator.

7.Drop blower end of burner assembly slightly down to clear control box and push all wires out of the way so that burner can be pulled out of tank.

8.Disconnect wires from the 195°F thermostat mounted to the generator and operating pressure switch.

9.Loosen hose clamp attaching lower flexible water line at back panel and use a wrench to disconnect barb fitting from main inlet water connection.

10.Loosen hose clamp attaching upper flexible water line at back panel and use a wrench to disconnect barb fitting from main inlet water connection.

11.Remove water line from generator. Remove steam hoses from steam trap and supply to super heater.

12.Disconnect gas tubing from rear panel

13.Remove steel drain tube at tank.

14.Disconnect union between tank and drain.

15.Loosen cable clamp screws securing electrical cable at rear panel so that cable is free to move.

16.Remove screws to free super heater and lift super heater off flue pipe.

F35425 (February 2006)

 