Vulcan-Hart C24GA6 ML-136021, C24GA10 ML-136022 service manual Operating Pressure Switch

Models: C24GA6 ML-136021, C24GA10 ML-136022 C24GA6, C24GA10, ML-136021, ML-136022

1 39
Download 39 pages 44.4 Kb
Page 15
Image 15
Operating Pressure Switch

C24GA SERIES CONVECTION STEAMERS - SERVICE PROCEDURES AND ADJUSTMENTS

16.Turn off the machine.

17.Re-install pilot, reconnect wire # 35.

18.Turn on the machine, let generator fill

19.Observe proper functioning of gas burner.

Operating Pressure Switch

1.Remove the cabinet base front panel as outlined under COVERS AND PANELS. Pressure switch is located behind control box.

2.Turn the power on and let the generator come up to pressure.

3.After the ready light comes on, turn one of the cooking compartment timers on to exhaust steam from the generator.

4.Observe generator pressure gauge reading for several cycles and verify that the burner is cycling off at 3.5 to 4 psi.

Page 15 of 40

 

F35425 (February 2006)

 

Page 15
Image 15
Vulcan-Hart C24GA6 ML-136021, C24GA10 ML-136022, C24GA6, C24GA10, ML-136021, ML-136022 Operating Pressure Switch