C24GA SERIES CONVECTION STEAMERS - ELECTRICAL OPERATION
Hold Thermostat | The Hold Thermostat energizes the Generator Slow Fill Solenoid Valve when |
| generator temperature reaches the |
Drain | The Drain is located on the lower right of the base and removes steam conden- |
| sate and water from cooking compartments and generator. |
Metal Fiber Main Burner | The Metal Fiber Main Burner is accessible from the front. This burner heats the |
| water in the generator to generate steam. |
Gas Combination Control Valve.... | The Gas Combination Control Valve is part of the Burner Assembly and is a |
| gas solenoid that opens to allow gas flow when a call for heat is made and that |
| also regulates the manifold gas pressure. |
Blower Motor | The Blower Motor is part of the Burner Assembly and provides airflow for the |
| metal fiber burner. The blower is accessible through the front of the base. |
Blower Air Pressure Switch | The Blower Air Pressure Switch is part of the Burner Assembly and closes at |
| 0.4" W.C. to apply operating voltage to the ignition module. |
Gas Orifice | The Gas Orifice is part of the Blower Assembly and controls the flow of gas to |
| the burner. |
Ignition Control Module | The Ignition Control Module controls the ignition of the gas pilot and main |
| burner. |
24 VAC Transformer | The 24 VAC Transformer reduces the input 120 VAC to the 24 VAC required by |
| the Ignition Module. |
Super Heater Assembly | The Super Heater Assembly (Heat Exchanger) is located at the rear of the |
| base surrounding the flue and is used to raise the temperature of the steam by |
| passing the steam around the flue assembly. |
Drain Valve Timer | The Drain Valve Timer turns on for 1000 seconds when Power On/Off Switch |
| is set to off position to operate the Drain Solenoid. |
5 PSI Pressure Relief Valve | The 5 psi Pressure Relief Valve opens if the generator pressure exceeds 5 psi |
| to prevent further pressure rise. |