C24GA SERIES CONVECTION STEAMERS - REMOVALAND REPLACEMENT OF PARTS
16.Rotate pressure relief valve coupling to allow pressure relief valve to be rotated about 90° so that valve is below generator top level.
17.Remove pressure switch from generator.
19.Move any interfering components out of the way, then push generator slightly forward to disengage feet and remove generator from rear of cabinet.
20.Reverse procedure to install generator.
FILL AND COLD WATER
SOLENOID VALVES
WARNING: DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT /
TAGOUT PROCEDURES.
1.Turn off the water supply to the steamer.
2.Remove front and side covers as outlined under
COVERS AND PANELS.
18. Remove bolts attaching front of generator to frame.
3. Pull the quick connect power leads off the solenoid valve being serviced.
Page 11 of 40 |
| F35425 (February 2006) |
|