PILOT/SPARK PROBE

C24GA SERIES CONVECTION STEAMERS - REMOVALAND REPLACEMENT OF PARTS

4.Disconnect the water lines for the solenoid valve being serviced and remove the solenoid valve from the unit.

5.Reverse procedure to install solenoid valve.

PILOT/SPARK PROBE

FLAME SENSOR

1.Remove main burner assembly as outlined under MAIN BURNER in REMOVALAND REPLACEMENT OF PARTS.

2.Remove the pilot assembly by disconnecting gas tube to the pilot burner and remove screws holding pilot assembly.

3.Replace the malfunctioning flame sensor or pilot assembly.

4.Reverse procedure to install a new flame sensor or pilot assembly.

5.Check for proper operation.