Vert-I-Pak Installation Recommendations
For proper unit performance and maximum operating life please refer to the minimum installation clearances below.
Figure 1
6" |
|
| B |
|
|
60" | 60" | A |
|
| |
SMALL RECESS OK | LARGER RECESS OK. IF A> 5xB | 60" | 60" | ||
|
|
|
60" |
| 60" |
|
| |
60" | 60" | 60" |
|
| |
60" | 60" |
|
6" | 6" | 12" |
|
|
Figure 2
Any time obstructions are present use the following guidelines for proper spacing from the
•For minor obstructions such as lamp poles or small shrubbery a clearance of 24" from the outdoor louver should be maintained.
•For major obstructions such as a solid fence, wall or other heat rejecting device like a condensing unit, a mini- mum distance of 72" should be kept.
BUILDING
| 60" | 24" |
|
VPAK | 12" | VPAK | VPAK |
|
|
| 24" |
| POLE |
| SHRUB |
|
|
| |
OUTDOOR |
|
| 72" |
CONDENSING |
|
|
|
UNIT | FENCE |
| |
| MAJOR OBSTRUCTION |
The above suggestions are for reference only and do not represent all possible installations. Please contact the factory for information regarding affects of other installation arrangements.
By following these simple recommendations you can be confident that your Friedrich