VERT-I-PAK® MODEL IDENTIFICATION GUIDE
MODEL NUMBER | V | E | A | 24 | K | 50 | RT | A | |
SERIES |
|
|
|
|
|
|
| ENGINEERING CODE |
|
|
|
|
|
|
|
| OPTIONS | ||
V=Vertical Series |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| RT = Standard Remote Operation | ||
E=Cooling with or without electric heat |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| SP = Seacoast Protected | ||
H=Heat Pump |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| ELECTRIC HEATER SIZE | ||
DESIGN SERIES |
|
|
|
|
|
| |||
|
|
|
|
|
| ||||
A = 32" and 47" Cabinet |
|
|
|
|
|
| |||
|
|
|
|
| 00 | = No electric heat | |||
|
|
|
|
|
| ||||
NOMINAL CAPACITY |
|
|
|
|
| 25 | = 2.5 KW | ||
|
|
|
|
| 34 | = 3.4 KW | |||
|
|
|
|
| |||||
|
|
|
|
| 50 | = 5.0 KW | |||
09 = 9,000 |
|
|
|
|
| ||||
|
|
|
|
| 75 | = 7.5 KW | |||
12 = 12,000 |
|
|
|
|
| ||||
|
|
|
|
| 10 | = 10 KW | |||
18 = 18,000 |
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
| |
24 = 24,000 |
|
|
|
|
|
|
|
|
|
VOLTAGE |
|
|
|
|
|
|
|
|
|
K = |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Vert-I-Pak® Chassis Specifications
MODEL: V(E,H)A24
Voltage (V)
Refrigerant Chassis Width Chassis Depth Chassis Height ** Supply Duct Collar ***
Drain Connection Min. Circuit Amps CFM Indoor Max. Duct ESP
230/208
23.125
23.125
47.25
10"
3/4" FPT
See Nameplate
See chart, pg. 11
.4 in. water
NOTES:
**Height includes 2" duct collar & isolators under unit.
***Factory collar accepts 10" flex duct.
4