ADJUSTING THE DIRECTION OF AIR CIRCULATION

Adjust the up, down, left, and right AIR directions with the AIR DIRECTION buttons on the Remote Controller.

Use the AIR DIRECTION buttons after the Indoor Unit has started operating and the airfl ow-direction louvers have stopped moving.

Vertical Air Direction Adjustment

Press the SET button (Vertical) (Fig. 6 b9).

Each time the button is pressed, the air direction range will change as follows:

1 2 3 4 5 6

Types of Air flow Direction Setting:

For better heating/cooling effect, it is recommended to set the air direction in the follow- ing range.

1,2,3 : During Cooling/Dry modes

4,5,6 : During Heating mode

The Remote Controller’s display does not change.

1

2

3

4

5

6

Use the air direction adjustments within the ranges shown above.

The vertical airfl ow direction is set automatically as shown, in accordance with the type of operation selected.

During Cooling/Dry mode

:

Horizontal fl ow 1

During Heating mode

:

Downward fl ow 5

During AUTO mode operation, for the fi rst minute after beginning operation, airfl ow will be horizontal 1; the air direction cannot be adjusted during this period.

Direction 1 2

Only the direction of the Air Flow Direction Louver changes; the direction of the Power Diffuser does not change.

The air fl ow direction setting will temporarily become 6 when the temperature of the air fl ow is low at the start of the Heating mode.

After beginning of AUTO/HEAT mode operated and automatic defrosting operation time (see page 15), the airfl ow will be horizontal 6.

However, the Airflow Direction cannot be adjusted at beginning AUTO operation mode.

Horizontal Air Direction Adjustment

Press the SET button (Horizontal)(Fig. 6 b10).

Each time the button is pressed, the air direction range will change as follows:

1 2 3 4 5

The remote controller’s display does not change.

DANGER!

Never place fi ngers or foreign objects inside the outlet ports, since the internal fan oper- ates at high speed and could cause per- sonal injury.

Always use the Remote Controller’s SET button to adjust the vertical airfl ow louvers. Attempting to move them man- ually could result in improper operation; in this case, stop operation and restart. The louvers should begin to operate properly again.

During use of the Cooling and Dry modes, do not set the Air Flow Direction Louvers in the Heating range (4 - 6) for long periods of time, since water va- por may condense near the outlet lou- vers and drops of water may drip from the air conditioner. During the Cooling and Dry modes, if the Air Flow Direction Louvers are left in the heating range for more than 30 minutes, they will auto- matically return to position 3.

When used in a room with infants, chil- dren, elderly or sick persons, the air direction and room temperature should be considered carefully when making settings.

1

2 3 4 5

En-10

9315345288_OM.indb 10

2/24/2010 1:36:25 PM

Page 11
Image 11
Friedrich 9315345288 manual Adjusting the Direction of AIR Circulation, En-10, Types of Air flow Direction Setting

9315345288 specifications

Friedrich 9315345288 is a standout model in the realm of portable air conditioning units, designed to provide efficient and effective cooling solutions for residential and commercial spaces. Recognized for its blend of performance, durability, and user-friendly features, this model answers the needs of individuals seeking relief from heat without compromising on convenience.

One of the key characteristics of the Friedrich 9315345288 is its powerful cooling capacity. With a BTU rating typically around 12,000, it can effectively chill spaces up to 550 square feet, making it an excellent choice for medium-sized rooms. The unit operates quietly, which is a crucial factor for users who value peace in their living or working environments. Its noise levels are kept to a minimum due to advanced engineering, making it suitable for bedrooms, offices, or any area requiring a quiet atmosphere.

In terms of energy efficiency, the Friedrich 9315345288 stands out with its high Energy Efficiency Ratio (EER). This feature not only helps in lowering electricity bills but also reflects a commitment to environmentally friendly cooling solutions. Furthermore, it is equipped with a programmable timer and adjustable thermostat, allowing users to customize their cooling schedules to align with their daily routines.

The unit is designed with ease of use in mind, featuring a straightforward digital control panel with remote control access for added convenience. Users can easily manage settings, change modes, and adjust fan speeds at a distance. The Friedrich 9315345288 offers multiple fan speeds and cooling modes, including a dehumidification option that efficiently reduces excess humidity in the air, enhancing indoor comfort.

The construction of the Friedrich 9315345288 is robust, featuring high-quality materials that ensure longevity and reliability. Its portable design includes caster wheels, making it easy to move from room to room as needed. The unit also includes a washable air filter that promotes better air quality and requires minimal maintenance.