Friedrich MR30C3G, MW36C3G, MW30C3G, MR36C3G Troubleshooting, En-13, Symptom, Problem

Models: MR36C3G MR30C3G MW30C3G MW36C3G

1 20
Download 20 pages 2.28 Kb
Page 14
Image 14
TROUBLESHOOTING

TROUBLESHOOTING

In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the electrical

WARNING! breaker or disconnect the power supply plug, and consult authorized service personnel.

Merely turning off the unit’s power switch will not completely disconnect the unit from the power source. Always be sure to turn off the electrical breaker or disconnect the power supply plug to ensure that power is completely off.

Before requesting service, perform the following checks:

 

Symptom

Problem

See Page

 

 

 

 

NORMAL

Doesn’t operate immedi-

● If the unit is stopped and then immediately started again, the com-

 

FUNCTION

ately:

pressor will not operate for about 3 minutes, in order to prevent fuse

 

 

 

blowouts.

 

 

● Whenever the Power Supply Plug is disconnected and then recon-

 

 

 

 

 

nected to a power outlet, the protection circuit will operate for about

 

 

 

3 minutes, preventing unit operation during that period.

 

 

 

 

 

 

Noise is heard:

● During operation and immediately after stopping the unit, the sound

 

 

 

of water flowing in the air conditioner’s piping may be heard. Also,

 

 

 

noise may be particularly noticeable for about 2 to 3 minutes after

 

 

 

starting operation (sound of coolant flowing).

 

 

● During operation, a slight squeaking sound may be heard. This is

 

 

 

the result of minute expansion and contraction of the front cover due

 

 

 

to temperature changes.

 

 

 

 

 

 

Smells:

● Some smell may be emitted from the indoor unit. This smell is the

 

 

result of room smells (furniture, tobacco, etc.) which have been taken

 

 

into the air conditioner.

 

 

 

 

 

 

Mist or steam are

● During Cooling or Dry operation, a thin mist may be seen emitted

 

 

emitted:

from the indoor unit. This results from the sudden Cooling of room air

 

 

by the air emitted from the air conditioner, resulting in condensation

 

 

 

 

 

and misting.

 

 

 

 

 

 

Airflow is weak or stops:

● The fan may operate at very low speed during Dry operation or when

6

 

 

the unit is monitoring the room’s temperature.

 

 

 

 

 

 

 

 

 

● During SUPER QUIET operation, the fan will operate at very low

6

 

 

speed.

 

 

 

 

 

 

 

 

 

● In the monitor AUTO operation, the fan will operate at very low

6

 

 

speed.

 

 

 

 

 

 

 

En-13