DIGITAL CONTROL DIAGNOSTICS

The chart below lists malfunctions and their description.

1

Indoor air temp sensor open/short

Display ‘F1’, with STATUS light flash

 

 

 

2

Indoor coil sensor open or short

Display ‘F2’, with STATUS light flash

 

 

 

3

Outdoor coil sensor open/short

Display ‘F4’, with STATUS light flash

 

 

 

4

Freeze Guard protection

Display ‘FP’, with STATUS light flash

 

 

 

5

Indoor coil high temp protection

STATUS light flash 8 times and off 3 sec, repeat

 

 

 

6

Outdoor coil high temp protection

STATUS light flash 6 times and off 3 sec, repeat

 

 

 

7

Indoor coil freeze protection

STATUS light flash 5 times and off 3 sec, repeat

 

 

 

8

Defrost (heat pump type)

STATUS light flash 7 times and off 3 sec, repeat

 

 

 

9

Thermostat wiring error

STATUS light flash 9 times and off 3 sec, repeat

 

 

 

23

Page 25
Image 25
Friedrich PTAC - R410A service manual Digital Control Diagnostics