Specifications and PERFORMANCE DATA
Cooling Performance Data
| EVAPORATOR AIR |
|
|
|
|
| OPERATING | ELECTRICAL RATINGS |
| BREAKER | |||||
| TEMP. DEG. F | CONDENSER | Discharge | Suction | Super | Sub- | PRESSURES |
| FUSE | ||||||
|
|
|
|
|
| ||||||||||
| Discharge |
| TEMPERATURE | Temp | Temp | Heat | Cooling |
|
|
|
| Locked Rotor |
| Voltage | 60 Hertz |
| Temp. Drop F. | DEG. F | Suction | Discharge | Amps Cool | Amps Heat | Charge in OZ. |
| |||||||
| Air |
|
|
|
|
|
|
|
|
|
| Amps |
|
| Amps |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
SH15M30A | 54 | 26 | 127 | 186 | 67 | 18 | 35 | 137 | 480 | 6.9 | - | 43 | 50 | 208 / 230 | 15 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
SH15M30A | 54 | 26 | 185 | 124 | 68 | 15 | 38 | 137 | 485 | 9.1 | - | 43 | 42.7 | 208 / 230 | 15 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Specications
|
|
|
|
|
|
|
|
|
| Energy |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Efciency | Moisture | Air Direction | Room Side Air | ||||
| Cooling Capacity |
| Electrical Characteristics (60 Hertz) |
| Ratio AHAM | Removal | Controls | Circulation | ||||||||
Model | (BTU/Hr.- AHAM) | Volts Rated | Amps AHAM | Watts |
|
| EER | (Pints/ Hr.) |
|
|
| CFM | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
SH15M30A | 14500/14000 |
| 230/208 |
| 6.9/7.4 | 1495/1443 |
| 9.7/9.7 |
| 6.0 |
|
| 375 | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
SH20M30A | 19500/19000 |
| 230/208 |
| 9.1/10.0 | 2074/2021 |
| 9.4/9.4 |
| 4.0 |
|
| 375 | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
Installation Information |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| Dimensions |
|
|
|
|
|
|
|
| Circuit Rating |
|
| |
|
|
|
|
|
|
| Window Width | Breaker or | Weight | |||||||
|
|
|
| (Inches) |
|
|
|
|
| |||||||
|
|
|
|
|
|
| (Inches) | Finished Hole (Inches) | T - D Fuse |
| (Lbs.) | |||||
|
|
|
|
|
|
|
|
| ||||||||
|
|
| Depth | Depth J Box | Minimum | Minimum |
|
|
|
|
|
|
|
|
| |
Model | Height | Width | Overall | to Louvers | Extension | Extension | Min. | Max . | Height | Width | Max. Depth | Volts - Amps | Net | Shipping | ||
(A) |
|
| Into Room | Outside | ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
SH15M30A | 15 15/16 | 25 15/16 | 27 3/8 | 6 |
| 3 1/16 | 16 15/16 | 27 7/8 | 42 | 16 3/16 | 26 3/16 | 6 | 250V | - 15A | 156 | 168 |
SH20M30A | 17 15/16 | 25 15/16 | 27 3/8 | 6 |
| 3 1/16 | 16 15/16 | 27 7/8 | 42 | 18 3/16 | 26 3/16 | 6 | 250V | - 15A | 160 | 174 |
Due to continuing engineering research and technology, specifications are subject to change without notice. Manufactured under U.S. Design Patent DES 368, 306 decorative front; Utility Patent 5, 622, 058. MAXIMUM outdoor ambient operating temperature is 130°F. MAXIMUM TEMPERATURE RATING FOR CLASS I, DIVISION 2, GROUPS A,B,C,D.
OPERATING TEMPERATURE CODE T3B
STANDARD ON ALL M ODEL S.
This advanced corrosion protection treatment protects the outdoor coil against deterioration and extends the life of the unit especially in harsh coastal environments.
(A)
Max.
Wall
Depth
SIDE VIEW
R-410A
Junction
Box
All models use
environmentally
Frontfriendly
7 | 7 |