TROUBLESHOOTING

Problem

Possible Cause

Possible Solution

 

Defective switch (On-Off)

Check continuity across terminals 2 and 3.

 

 

 

 

Fan capacitor open.

Test with capacitor analyzer. Replace if bad.

 

Inoperative fan motor.

Check power and if okay, perform continuity test.

 

Replace if bad.

 

 

Fan motor does

Incorrect wiring of fan circuit.

Connect per wiring diagram.

not run.

 

 

Solid state relay open.

Replace relay.

 

 

 

 

 

Seized motor bearings.

Replace motor.

 

 

 

 

Bound fan blade or blower wheel.

Adjust for proper clearance.

 

 

 

Problem

Possible Cause

Possible Solution

 

 

 

Switch (On-Off)

Defective (On-Off) switch or

 

does not cut fan

Replace switch or relay.

defective relay.

motor off.

 

 

 

Problem

Possible Cause

 

 

 

 

 

Poor installation.

Refer to installation instructions for proper

 

installation.

 

 

 

Fan blade striking chassis or

Adjust fan blade or blower wheel clearance.

 

blower wheel housing.

Noisy and/or

 

 

Check for deteriorated compressor grommets.

vibration.

Compressor vibrating.

Replace as needed.

 

 

 

 

 

 

Loose cabinet parts, improperly

 

 

mounted components, tubing

Adjust and tighten as required.

 

rubbing.

 

Problem

Possible Cause

Possible Solution

 

 

 

 

Evaporator drain pan overflowing.

Clean obstructed drain trough.

Water leaks into

Condensation forming on bottom of

Evaporator drain pan broken or cracked. Replace

base pan.

chassis seal gasket missing or defective.

room.

Water dripping from discharge air

Dirty evaporator coil, or extremely high humidity

 

 

grilles.

conditions. Clean coil or check application.

Problem

Possible Cause

Possible Solution

 

 

 

 

Extremely high humid conditions.

Install 01900-235 drain kit.

 

Water in center section of base pan

Drain trough. Check level. Ensure 1/4” tilt toward

Excessive water

(compressor area).

rear.

leaks outside.

Dirty condenser coil.

Clean with steam or detergent.

 

Fan blade and slinger ring

Adjust fan blade to 1/2” clearance from condenser

 

improperly positioned.

coil.

26

Page 27
Image 27
Friedrich R-410A service manual Problem Possible Cause

R-410A specifications

Friedrich R-410A is an advanced refrigerant widely used in HVAC (Heating, Ventilation, and Air Conditioning) systems, known for its high efficiency and environmental friendliness. As a hydrofluorocarbon (HFC) blend, R-410A has become the preferred alternative to R-22, which is being phased out due to its ozone-depleting potential. One of the main features of R-410A is its high latent heat of vaporization, which allows for efficient heat transfer and improved cooling performance in air conditioning units.

Technologically, R-410A operates at higher pressures than older refrigerants, meaning systems designed for R-410A need to be built with more robust components to safely handle these pressures. This results in a more compact system design that offers enhanced performance and reliability. The dual-component nature of R-410A—composed of difluoromethane (R-32) and pentafluoroethane (R-125)—provides an optimal balance of thermodynamic properties, leading to superior energy efficiency, especially in variable speed applications.

In terms of characteristics, R-410A has a higher cooling capacity, which enables HVAC systems to effectively cool larger spaces or run more efficiently when cooling smaller areas. The refrigerant is non-toxic and non-flammable, which enhances safety during its use. In addition, R-410A has a lower global warming potential relative to other refrigerants, making it a more environmentally responsible choice for modern cooling systems.

Moreover, R-410A systems typically require less refrigerant charge due to their efficiency, contributing to reduced greenhouse gas emissions. The adoption of R-410A aligns with regulatory trends aimed at minimizing the environmental impact of refrigerants in cooling applications.

Overall, the Friedrich R-410A refrigerant embodies a combination of technology and environmental stewardship, making it a cornerstone of contemporary HVAC design. Its ability to provide effective and energy-efficient cooling solutions while being compliant with modern environmental regulations positions R-410A as the refrigerant of choice for engineers and installers focused on sustainability and performance in air conditioning systems.