Electrical Rating Tables

Electrical Rating Tables

 

Circuit Rating

Plug Face

Appearance

Model

Breaker or T-D Fuse

(NEMA#)

(Facing Blades)

 

 

 

 

ALL SV and XQ MODELS,

 

 

 

KS10J10, KS12J10B, KS15J10, RS10J10, RS12J10A,

 

 

 

RS15J10, SS08J10R, SS09J10C, SS10J10AR,

125V - 15A

5 - 15P

 

SS12J10AR, SS14J10R, SC06H10D,

 

 

 

 

EQ08J11, YQ06J10B, YS09J10B

 

 

 

 

 

 

 

KS12J30B, KM18J30C, RS16J30A,

250V - 15A

6 - 15P

 

RM18J30A, SS12J30D, SS16J30A, SM18J30BR

 

 

 

 

 

 

 

 

KM20J30, KM24J30, SM20J30,

 

 

 

SL25J30, SL28J30B*, ES12J33B,

250V - 20A

6 - 20P

 

ES16J33A, YS12J33

 

 

 

 

 

 

 

SL35J30, EM18J34B, EL25J35, EL35J35,

250V - 30A

6 - 30P

 

YM18J34B, YL24J35C

 

 

 

 

 

 

 

 

*Optional 30 Amp Kit (618-869-00) is recommended in 208 Volt power supply areas that fall below 208 Volts. For more information, call the Friedrich Service Department.

Due to a program of continuing improvement, specifications are subject to change without notice.

Installation Notes:

Supply Cord - All with right angle plug 6' on 115V; 5' on 230/208V.

Room air conditioners include accessories for window or thru-the-wall installation. TWINTEMP® models include accessories for thru-the-wall installation only. Window mounting requires use of optional accessory kit as listed below:

MODEL

KIT NO.

EQ08J11, YQ06J10B

WIKQ

 

 

ES12J33B, ES16J33A,

WIKS

YS09J10B, YS12J33

 

 

 

EM18J34B, YM18J34B

WIKM

 

 

EL25J35, EL35J35,

WIKL

YL24J35C

 

 

 

Wire Size

Use ONLY wiring size recommended for

 

single outlet branch circuit.

Fuse/Circuit

Use ONLY type and size fuse or HACR

Breaker

circuit breaker indicated on unit's rating

 

plate. Proper current protection to the unit

 

is the responsibility of the owner.

Grounding

Unit MUST be grounded from branch circuit

 

through service cord to unit, or through

 

separate ground wire provided on permanently

 

connected units. Be sure that branch circuit

 

or general purpose outlet is grounded.

Electric shock hazard.

Turn off electric power before service or installation.

All electrical connections and wiring MUST be installed by a qualified electrician and conform to the National Electrical Code and all local codes which have jurisdiction.

Failure to do so can result in property damage, personal injury and/ or death.

Receptacle The field supplied outlet must match plug on service cord and be within reach of service cord.

Do NOT alter the service cord or plug. Do NOT use an extension cord. Refer to the table above for proper receptacle and fuse type.

The consumer - through the AHAM Room Air Conditioner Certification Program - can be certain that the AHAM Certification Seal accurately states the unit's cooling and heating capacity rating, the amperes and the energy efficiency ratio.

13