Troubleshooting: Cooling

PROBLEM

POSSIBLE CAUSE

TO CORRECT

 

 

 

 

Low voltage.

Check for voltage at compressor. 115 volt and 230

 

Thermostat not set cold enough or

volt units will operate at 10% voltage variance

 

Set thermostat to coldest position. Test thermostat

Compressor does not

inoperative.

and replace if inoperative.

run.

Compressor hums but cuts off on

Hard start compressor. Direct test compressor. If

 

overload.

compressor starts, add starting components.

 

Open or shorted compressor

Check for continuity and resistance.

 

windings.

 

 

Open overload.

Test overload protector and replace if inoperative.

 

Open capacitor.

Test capacitor and replace if inoperative.

 

Inoperative system switch.

Test for continuity in all positions. Replace if

 

Broken, loose or incorrect wiring.

inoperative.

 

Refer to appropriate wiring diagram to check wiring.

 

 

 

 

PROBLEM

POSSIBLE CAUSE

TO CORRECT

 

 

 

 

 

 

Inoperative system switch.

Test switch and replace in inoperative.

 

 

Broken, loose or incorrect wiring.

Refer to applicable wiring diagram.

 

Fan motor

Open Capacitor.

Test capacitor and replace if inoperative.

 

does not run.

Fan speed switch open.

Test switch and replace if inoperative.

 

 

Inoperative fan motor.

Test fan motor and replace if inoperative. (Be

 

 

 

sure internal overload has had time to reset.)

 

 

 

 

 

 

 

 

 

PROBLEM

POSSIBLE CAUSE

TO CORRECT

Does not cool, or cools

only slightly.

Undersized unit.

Thermostat open or inoperative.

Dirty filter.

Dirty or plugged condenser or evaporator coil.

Poor air circulation in area being cooled.

Fresh air or exhaust air door open on applicable models.

Low capacity – undercharge. Compressor not pumping properly.

Refer to Sizing Charts.

Set to coldest position. Test thermostat and replace if necessary.

Clean as recommended in Owner’s Manual. Use steam or detergents to clean.

Adjust discharge air louvers. Use high fan speed.

Close doors. Instruct customer on use of this feature.

Check for leak and make repair.

Check amperage draw against nameplate. If not conclusive, make pressure test.

PROBLEM

 

TO CORRECT

 

 

 

 

 

 

Fuse blown or circuit tripped.

Replace fuse, reset breaker. If repeats, check fuse

 

 

or breaker size. Check for shorts in unit wiring and

 

 

 

Unit does not run.

 

components.

 

 

Power cord not plugged in.

Plug in power cord

 

 

System switch in "Off" position.

Set switch correctly.

 

 

Inoperative system switch.

Test for continuity in each switch position.

 

 

Loose or disconnected wiring at switch or

Check wiring and connections. Reconnect per wiring

 

 

other components.

diagram.

36

Page 36
Image 36
Friedrich racservmn service manual Troubleshooting Cooling, Problem To Correct

racservmn specifications

Friedrich Racervmn is an innovative name in the realm of precision engineering, making significant strides in the development of advanced technologies for various industries. This company stands out due to its commitment to creating high-quality, reliable, and efficient products that cater to the diverse needs of its clientele.

One of the main features of Friedrich Racervmn is its focus on research and development. The company invests heavily in R&D to push the boundaries of what is technically possible. This dedication results in the continuous improvement of their product line and the introduction of cutting-edge solutions that leverage the latest advancements in technology.

Among the distinctive technologies used by Friedrich Racervmn is their proprietary manufacturing process, which integrates automation and robotics to enhance efficiency and precision. This not only speeds up production times but also ensures that the products maintain a consistently high quality. The use of Computer Numerical Control (CNC) machines in their processes allows for intricate designs and complex geometries that meet rigorous industry standards.

Moreover, Friedrich Racervmn utilizes innovative materials in their products to ensure durability and performance under various conditions. These materials are selected based on their specific properties, such as strength, weight, and resistance to environmental factors, ensuring that the final output exceeds customer expectations.

Another hallmark of Friedrich Racervmn is their commitment to sustainability. The company actively seeks ways to minimize its environmental footprint by optimizing resource use and incorporating eco-friendly practices throughout its manufacturing processes. This is reflected in their efforts to design products that are not only high-performing but also energy-efficient, helping customers reduce their carbon emissions.

Friedrich Racervmn’s customer service stands out as well. Their team is dedicated to providing exceptional support, ensuring that clients receive personalized attention and solutions tailored to their unique needs. This customer-centric approach is a fundamental part of their philosophy and has contributed to building strong and lasting relationships within the industry.

In summary, Friedrich Racervmn is a leader in precision engineering, recognized for its advanced technologies, innovative manufacturing processes, commitment to sustainability, and outstanding customer service. The company’s focus on quality and innovation positions it as a vital player in the modern industrial landscape, continuously pushing the envelope toward a more technologically advanced and environmentally conscious future.