Friedrich racservmn service manual Ss Performance Data

Models: racservmn

1 64
Download 64 pages 23.92 Kb
Page 8
Image 8

SS PERFORMANCE DATA

PERFORMANCE

EVAPORATOR AIR

OPERATING

ELECTRICAL

R-22

BREAKER

DATA*

TEMP. DEG. F.

PRESSURES

RATINGS

REFRIG.

FUSE

Cooling

 

 

 

 

 

 

 

 

Discharge

Temp.

Suction

Discharge

Amps

Locked

Charge in

60 Hertz

 

Air

Drop F.

 

 

 

Rotar Amp

OZ.

Amps

 

 

 

 

 

 

 

 

 

SS08J10R-B

61.4

18.6

87

251

6.7

29

39.'0

15

SS08J10R-A

61.4

18.6

84

248

6.7

36.2

24.'0

15

SS09J10C-A

57.8

22.2

82

254

7.4

44

22.6

15

SS10J10AR-A

57.22

22.78

84

245

7.5

42

26.'0

15

SS12J10AR-B

57.2

22.8

83

271

9.8

44

30.'0

15

SS14J10R-A

57.22

22.9

77

279

12

61

29.5

15

SS12J30D-A

57.2

22.8

82

265

5.0/5.2

21

27.5

20

SS16J30A-A

56.9

23

77

296

7.5/8.0

28

30.'0

20

SS18J30R-A

56.9

23

77

293

8.1/8.7

45

48

20

 

 

 

 

 

 

 

 

 

SM-SL PERFORMANCE DATA

PERFORMANCE

EVAPORATOR AIR

OPERATING

ELECTRICAL

R-22

BREAKER

DATA*

TEMP. DEG. F

PRESSURES

RATINGS

REFRIG.

FUSE

Cooling

Discharge

Temp

Suction

Discharge

Amps

Locked

Charge in

60 Hertz

 

Air

Drop F.

 

 

 

Rotar Amp

OZ.

Amps

SM20J30-A

52.58

27.42

70

279

9.9

43

47

20

SM24J30-A

54.86

25.14

68

301

12.2

68

54

20

SL25J30-A

52.32

27.68

75

284

11.5/12.6

68

48.5

20

SL28J30B-A

52.1

26.9

74

278

13.0/14.2

88

50

20

SL35J30-A

52.93

27.07

72

317

18.0/20.0

92

60

30

SL35J30-B

52.93

27.07

72

317

18.0/20.0

92

60

30

 

 

 

 

 

 

 

 

 

*Rating Conditions: 80 degree F. Room Air Temperature and 50% Relative Humidity with 95 degree F. Outside Air Temperature at 40% Relative Humidity.