One-Year Warranty (cont.)
IMPORTER:
INTERNACIONAL DE CERÁMICA, S.A.B. DE C.V.
AV. CARLOS PACHECO NO. 7200
CHIHUAHUA, CHIH., MEXICO C.P. 31060
TEL: 52 (14)
Troubleshooting
This troubleshooting guide is for general aid only. A Kohler Authorized Service Representative or qualified electrician should correct any electrical problems. For warranty service, contact your dealer or wholesale distributor.
Symptoms | Probable Causes | Recommended Action | |||
1. | Urinal does not | A. | Batteries are not | A. | Verify batteries are |
| flush. |
| installed or batteries |
| installed or are |
|
|
| are reversed. |
| installed properly. |
|
| B. | Other objects are | B. | Remove objects in |
|
|
| being detected. |
| proximity of the |
|
|
|
|
| urinal or adjust the |
|
|
|
|
| induction distance. |
|
|
|
|
| Refer to the ″Adjust |
|
|
|
|
| the Induction |
|
|
|
|
| Distance″ section of |
|
|
|
|
| this guide. |
|
| C. | Dirty sensor | C. | Clean the sensor |
|
|
| window. |
| window. Refer to |
|
|
|
|
| the ″Care and |
|
|
|
|
| Cleaning″ section of |
|
|
|
|
| this guide for |
|
|
|
|
| recommended |
|
|
|
|
| cleaners. |
2. | The lamp on | A. | Ten minutes have | A. | Wait ten minutes |
| the battery |
| not passed since |
| for activation. |
| indicator |
| batteries have been |
|
|
| flashes once |
| replaced. The urinal |
|
|
| when a user or |
| is still in adjustment |
|
|
| object is |
| mode. |
|
|
| present, but | B. | Control stop and/or | B. | Open the control |
| little or no |
| supply stop is |
| stop and/or supply |
| water is |
| closed. |
| stop. |
| present. | C. | The water pressure | C. | Increase the water |
|
|
| is low. |
| supply pressure. |
|
|
|
|
| |
|
|
|
|
| |
Kohler Co. |
| 9 |
|