Kohler K4915 Adjust the Induction Distance, Decrease, Increase, Plug Cover, Kohler Co, 085788-5-D

Models: K4915

1 40
Download 40 pages 37.27 Kb
Page 5
Image 5
Decrease

 

Decrease

Increase

Plug Cover

Control Unit

Distance Potential

Screw

Adjust the Induction Distance

NOTE: The induction distance is set to a maximum and will not usually require adjustment. However, if a toilet or any other fixtures are nearby, adjustment may be needed.

NOTE: The unit is set to adjustment mode for 10 minutes after the batteries have been inserted. In adjustment mode, the urinal will not flush, but the battery indicator lamp will flash once when a user is detected. If adjustment takes longer than 10 minutes, remove and reinsert the batteries.

Lift the control unit out from the tank.

Remove and retain the plug cover on the control unit to reveal the distance potential screw.

NOTICE: Only use a micro Phillips screwdriver when adjusting the induction distance. If the tip of the micro Phillips screwdriver is too large, the potentiometer may become damaged.

Using a micro Phillips screwdriver, turn the distance potential screw to adjust the induction distance. To increase the distance, turn the screw counterclockwise. To decrease the distance, turn the screw clockwise.

Reinstall the plug cover.

Place the control unit back into the tank.

Kohler Co.

5

085788-5-D

Page 5
Image 5
Kohler K4915 manual Adjust the Induction Distance, Decrease, Increase, Plug Cover, Control Unit Distance Potential Screw