Friedrich SP05A10 service manual 4-2Checking the oil, 4-2-1Oil quality

Models: SP05A10

1 28
Download 28 pages 19.6 Kb
Page 11
Image 11
4-2 Checking the oil

4-2 Checking the oil

Fill the transparent container with 10cc of oil, and then conduct the test.

4-2-1 Oil quality

Condition of

 

Oil Condition

Remarks

Refrigerant Cycle

Color

 

Odor

 

 

 

 

 

 

 

Normal

Straw Yellow

 

No Odor

Return with the system

 

 

 

 

 

Over-heated

Brown Color

 

-

Change the oil

 

 

 

 

 

Compressor Damage

Dark Brown

 

Pungent oil

Change the oil

 

 

 

 

 

4-2-2 Replacing and refilling the refrigerant oil

1.Change the compressor - DO NOT recharge the oil as the compressor itself is already charged.

2.Change the condenser .... add 50cc

3.Change the evaporator .... add 50cc

4.When the refrigerant is replaced .... add 30cc oil.

5.After vacuum is completed, the oil is filled through the high pressure side.

6.In the event of a refrigerant leak, generally it is not necessary to add oil. (Unless the oil has leaked significantly.)

4-2

FRIEDRICH AIR CONDITIONING CO.

Page 11
Image 11
Friedrich SP05A10 service manual 4-2Checking the oil, 4-2-1Oil quality, 4-2-2Replacing and refilling the refrigerant oil