Friedrich SP05A10 service manual Disassembly and Reassembly, 4-1Compressor Replacement Flow Chart

Models: SP05A10

1 28
Download 28 pages 19.6 Kb
Page 10
Image 10
4. Disassembly and Reassembly

4. Disassembly and Reassembly

4-1 Compressor Replacement Flow Chart

 

 

Locate cause of defect

 

 

 

Release refrigerant

 

 

 

Disconnect electrical wiring

 

 

 

from compressor

 

 

 

Cut refrigerant lines

 

 

 

from compressor

 

 

 

Plug disconnected lines

 

 

 

Replace compressor

 

Inspect electrical

Solder discharge line

Solder suction line

Use nitrogen gas

wiring for defects,

 

 

 

and terminals for

 

 

 

correct and secure

 

 

 

connections

 

 

 

 

 

 

Perform soldering function

Y

 

 

 

Problem?

 

 

 

 

 

 

Fill system with

 

 

 

nitrogen gas

N

 

 

 

 

 

 

Check for leakage

Corrective action

 

 

Y

Check refrigerant oil level

Leakage?

 

 

 

 

 

N

Release nitrogen gas?

YN

Low oil level?

Evacuate system

Add oil as necessary

Recharge system

Pinch and braze filling tube

FRIEDRICH AIR CONDITIONING CO.

4-1

Page 10
Image 10
Friedrich SP05A10 Disassembly and Reassembly, 4-1Compressor Replacement Flow Chart, Friedrich Air Conditioning Co