2.3.3 CAPACITOR

1. Remove the cabinet. (Refer to section 2.1.2)

2. Remove the screw and the clamp which fastens the capacitor.

3. Disconnect all the leads of capacitor terminals.

4. Re-install the components by referring to the removal procedure, above. (See Figure 11)

Tem

 

 

 

 

perat

 

 

 

 

ure

Med

 

 

 

Warmer

 

 

 

Fan

Off

 

Cooler

 

 

 

High

 

Low

 

 

Cool

 

Fan

 

 

 

 

 

Low

Cool

Med

 

 

 

 

 

 

 

Cool

Mode

Figure 11

2.3.4 POWER CORD

1.Remove the cabinet. (Refer to section 2.1.2)

2.Disconnect the grounding screw from the control box.

3.Disconnect the 2 receptacles.

4.Remove a screw which fastens the clip cord. (See Figure 12)

5.Remove the power cord.

6.Re-install the component by referring to the above removal procedure, above.

(Use only one ground-marked hole

for ground

connection.)

 

7.If the supply cord of this appliance is damaged, it must be replaced by the special cord. (The special cord means the cord which has the same specification marked on the supply cord attached at the unit.)

2.3.5 THERMOSTAT

1.Remove the cabinet. (Refer to section 2.1.2)

2.Remove the 2 screws which fasten the thermostat.

3.Disconnect 2 leads of thermostat terminals.

4.Remove the thermostat.

5.Re-install the components by refering to the above removal procedure. (See Figure 13)

2.3.6 ROTARY SWITCH

1.Remove the cabinet. (Refer to section 2.1.2)

2.Remove the 2 screws which fasten the rotary switch.

3.Disconnect all the leads of the rotary switch terminals.

4.Remove the rotary switch.

5.Re-install the components by referring to the above removal procedure. (See Figure 14)