Friedrich SV12A10, SV10A10, SV08A10 manual Refrigerating Cycle, Condenser, Evaporator

Models: SV10A10 SV08A10 SV12A10

1 27
Download 27 pages 14.54 Kb
Page 9
Image 9

2.3.7 MOTOR

1.Remove the cabinet. (Refer to section 2.1.2)

2.Remove the turbo fan. (Refer to section 2.2.1)

3.Remove the fan. (Refer to section 2.2.2)

4.Remove the 4 screws which fasten the motor from the Motor Mount. (See Figure 15)

5.Remove the motor.

6.Re-install the components by referring to the removal procedure, above.(See Figure 15)

2.4 REFRIGERATING CYCLE

2.4.1 CONDENSER

CAUTION

Discharge the refrigerant system using a FreonTM Recovery System.

If there is no valve to attach the recovery system, install one (such as a WATCO A-1) before venting the FreonTM. Leave the valve in place after servicing the system.

1.Remove the cabinet. (Refer to section 2.1.2)

2.Remove the 4 screws which fasten the brace.

3.Remove the 4 screws which fasten the condenser and shroud. (See Figure 16)

4.Remove the 2 screws which fasten the condenser and base pan.

5.After discharging the refrigerant completely, unbraze the interconnecting tube at the condenser connections.

6.Remove the condenser.

7.Re-install the components by referring to notes. (See Figure 16)

Figure 15

Figure 16

2.4.2 EVAPORATOR

1.Remove the cabinet. (Refer to section 2.1.2)

2.Remove the control box.(Refer to section 2.1.3)

3.Remove the upper air guide. (Refer to section 2.2.1)

4.Remove the 2 screws which fasten the evaporator from lower air guide.

5.Move the evaporator sideways carefully. (Refer to section 2.2.1)

6.After discharging the refrigerant completely, unbraze the interconnecting tube at the evaporator connections.

7.Remove the evaporator.

8.Re-install the components by referring to notes. (See Figure 17)

Figure 17

— 9—

Page 9
Image 9
Friedrich SV12A10, SV10A10, SV08A10 manual Refrigerating Cycle, Condenser, Evaporator