3. INSTALLATION
3.1 INSTALLATION HARDWARE
Window sash seal
Left frame curtain
Foam top window gasket
Frame guide(2) | Right frame |
Window locking | curtain |
bracket |
|
Sill support(2) |
|
Type A (13)
Type B (3)
Type C (5)
Nut (2)
Bolt (2)
3.2 SELECT THE BEST LOCATION
Step 1. To prevent vibration and noise, make sure the unit is installed securely and firmly
Step 2. If possible, install the unit where sunlight does not shine directly on the unit.
Step 3. The outside of the cabinet must extend outward for at least 11" and there should be no obstacles, such as a fence or wall, within 20" from the back of the cabinet because it will prevent heat radiation of the condenser.
Restriction of outside air will greatly reduce the cooling efficiency of the air conditioner.
Step 4. Install the unit with a little tilt outward not to leak the condensed water into the room (about 10~15cm or 1/4 bubble with level).
CAUTION: All side louvers of the cabinet must remain exposed to the outside of the structure.
COOLED
AIR
30"~60"
FENCE
AWNING
HEAT
RADIATION
About 1/2"
Over 20"
1/4 Bubble
Level
— 12—