Friedrich ZQ08A10C manual Refrigerating Cycle, Condenser, Evaporator, Capillary Tube, Figure

Models: ZQ08A10C

1 28
Download 28 pages 46.28 Kb
Page 9
Image 9
2.4 REFRIGERATING CYCLE

2.4 REFRIGERATING CYCLE

CAUTION

Discharge the refrigerant system using a FreonTM Recovery System.

If there is no valve to attach the recovery system, install one (such as a WATCO A-1) before venting the FreonTM. Leave the valve in place after servicing the system.

2.4.1 CONDENSER

1. Remove the cabinet. (Refer to section 2.1.2)

2. Remove the 3 screws which fasten the brace.(Refer to section 2.2.1)

3.Remove the 3 screws which fasten the condenser and shroud.

4.After discharging the refrigerant completely,

 

unbraze the interconnecting tube at the condenser

Figure 14

 

connections.

 

 

5.

Remove the condenser carefully.

 

6.

Re-install the component by referring to notes.

 

 

(See Figure 14)

 

2.4.2 EVAPORATOR

1. Remove the cabinet. (Refer to section 2.1.2)

2. Remove the 2 screws which fasten the evaporator.

3.Move the evaporator sideways carefully. (Refer to section 2.2.1)

4.After discharging the refrigerant completely, unbraze the interconnecting tube at the evaporator connections.

5.Remove the evaporator carefully.

6. Re-install the component by referring to notes. (See Figure 15)

Figure 15

2.4.3 CAPILLARY TUBE

1.Remove the cabinet. (Refer to section 2.1.2)

2.After discharging the refrigerant completely, unbraze the interconnecting tube at the capillary tube.(See caution above)

3.Remove the capillary tube.

4.Re-install the component by referring to notes.

— 9—

Page 9
Image 9
Friedrich ZQ08A10C manual Refrigerating Cycle, Condenser, Evaporator, Capillary Tube, Figure