FIRST STEPS (continued)
FAUCET ASSEMBLY INSTALLATION
•Attach faucet knob (9) to Faucet & Shank Assembly (6).
•Slip the Faucet & Shank Assembly (6) through the black plastic collar (7) (flat side toward door), Facade (3), and hole in door.
•Thread on the large Shank Nut (8) and tighten until snug, using an adjustable wrench. DO NOT over tighten.
SUMP VALVE INSTALLATION
•Place one rubber washer (5) on threaded end of sump valve (4).
•Slip sump valve with washer through hole in bottom of sump
(1).
•Place remaining rubber washer (5) over threaded end of sump.
•Thread plastic nut (5) onto threaded end of sump valve and tighten until snug.
•Make sure knob on valve is located to front for proper operation.
•Place Drip Tray (2) onto the Sump (1).
CAUTION
Replacing the faucet knob (9) with a longer knob is not recommended. This may interfere with the opening of the freezer door causing beverage spillage and/or damage to the faucet assembly and door.
SUMP AND DRIPTRAY ASSEMBLY INSTALLATION
•Remove bottom mounting screw.
•Align the two notched mounting tabs on back of sump (1) with upper mounting screws in door and push up.
•Install bottom mounting screw through slot and tighten.
REGULATOR INSTALLATION
•Check to ensure plastic washer is inside the hex nut.
NOTE
If the plastic washer is missing, please call Electrolux
Consumer Services at 1-800-944-9044 for assistance.
•Fasten the CO2 regulator (10) to the CO2 canister (16). Place the regulator to the right of the tank.
•Tighten the hex nut securely. DO NOT over tighten. Over tightening may damage the gasket in the nut of the regulator.
9