Frigidaire LCRT2010ST Service Information, Tools And Measuring Instruments, Necessary Tools

Models: LCRT2010ST

1 35
Download 35 pages 18.5 Kb
Page 11
Image 11
SERVICE INFORMATION

SERVICE INFORMATION

TOOLS AND MEASURING INSTRUMENTS

NECESSARY TOOLS

Tools normally used for TV servicing are sufficient.

Standard tools are listed below.

Diagonal pliers

Long nose pliers

Phillips screwdriver

Flat blade screwdriver

Wrench (size 5mm)

Nutdriver (size 5mm)

Adjustable wrench

Soldering iron

Solder

Vinyl insulation tape

Polishing cloth

NECESSARY MEASURING INSTRUMENTS

TESTER (VOLTS-DC, AC, Ohmmeter)

Microwave survey meter

-Holaday HI-1500

HI-1501

- Narda 8100 8200

Inch scale

600 cc non conductive material beaker (glass or plastic), inside diameter: approx. 8.5 cm (31/2 in.)

Cylindrical and made of borosilicate glass vessel. max. thickness: 3 mm

outside diameter: approx. 190mm

height: approx. 90mm

Glass thermometer: 100°C or 212°F (1 deg scale)

MICROWAVE LEAKAGE TEST

CAUTIONS

Be sure to check microwave leakage prior to servicing the oven if the oven is operative prior to servicing.

The service personnel should inform the manufacture, importer, or assembler of any certified oven unit found to have a microwave emission level in excess of 5 mW/cm2 and should repair any unit found to have excessive emission levels at no cost to the owner and should ascertain the cause of the excessive leakage. The service personnel should instruct the owner not to use the unit until the oven has been brought into compliance.

If the oven operates with the door open, the service personnel should:
-Tell the user not to operate the oven.

-Contact the manufacturer.

The service personnel should check all surface and vent openings for microwave leakage.

Check for microwave leakage after every servicing. The power density of the microwave radiation leakage emitted by the microwave oven should not exceed

4 mW/cm2. Always start measuring of an unknown field to assure safety for operating personnel from radiation leakage.

MEASURING MICROWAVE ENERGY LEAKAGE

Pour 275±15cc of 20±5°C(68±9°F) water in a beaker which is graduated to 600 cc, and place the beaker on the center of the turntable.

Set the energy leakage monitor to 2,450 MHz and use it following the manufacturer's recommended test procedure to assure correct result.

When measuring the leakage, always use the 2- inch (5 cm) spacer supplied with the probe.

Operate the oven at its maximum output.

Measure the microwave radiation using and electromagnetic radiation monitor by holding the probe perpendicular to the surface being measured

Move probe along shaded area
Probe scanning speed Less than 2.5 cm/sec (1 in/sec)

5-1

Page 11
Image 11
Frigidaire LCRT2010ST Service Information, Tools And Measuring Instruments, Microwave Leakage Test, Necessary Tools