Frigidaire LCRT2010ST service manual Condition, Check, Result, Cause, Remedy, 5-16

Models: LCRT2010ST

1 35
Download 35 pages 18.5 Kb
Page 26
Image 26
NOTE: • Make sure the wire leads correct position.

(TROUBLE 5) No microwave oscillation even though oven lamp and fan motor run. (Display operates properly)

CONDITION

No microwave oscillation.

CHECK

 

 

 

RESULT

 

 

 

 

 

 

 

 

 

 

Disconnect the

 

 

 

No continuity.

 

 

 

wire leads from

 

 

 

 

 

 

 

 

relay 2 and

 

 

 

 

 

 

 

 

check continuity

 

 

 

Continuity.

 

 

 

of relay2.

 

 

 

 

 

 

 

 

(Operate the unit)

 

 

 

 

 

 

 

 

 

CAUSE

Defective PCB assembly

REMEDY

Replace PCB assembly

Check high vol-

Abnormal

tage transformer

 

5-16 normal

Check high vol-

Abnormal

tage capacitor.

 

Manual background normal

Check high vol-

Abnormal

tage diode.

 

Manual background normal

Defective high voltage transformer.

Defective high voltage capacitor.

Defective high voltage diode.

Replace high voltage transformer.

Replace high voltage capacitor.

Replace high voltage diode.

Check

Abnormal

Defective

Magnetron.

magnetron.

 

Replace magnetron.

NOTE: • Make sure the wire leads correct position.

When Removing the wire leads from the parts, be sure to grasp the connector, not the wires.

When removing the magnetron, be sure to install the magnetron gasket in the correct position and in good condition.

Output is full power when you set lower power level.

Disconnect the wire leads from relay 2 and check continuity relay 2. (Operate the unit)

Manual background Abnormal.

Defective PCB assembly

Replace PCB assembly

5-16

Page 26
Image 26
Frigidaire LCRT2010ST Condition, Check, Result, Cause, Remedy, 5-16, NOTE Make sure the wire leads correct position