Installation
Tools required for installation Screw driver (pozidrive n°2 , torx 10 and 20) Allen spanner 4mm
Shifting spanner 10mm pipe wrench 3/8
Electric drill with twist bit Ø 10 mm
K = Kitchen Height |
|
C = Counter Height (36" standard) | |
P = Prefered Height of Hood | |
Bottom above counter |
|
(recommended | |
A = Canopy Height |
|
H = Hood height your installation | |
H = K – C – P |
|
S = Chimney Structure Height, | |
your installation. |
|
S = H – A |
|
S | H |
| A |
K |
|
P |
|
C | (36"std.) |
Figure 2 |
|
Figure 3 |
Figure 4 | Figure 5 |
1.a) Select a hood preference height P (see Figure 2) that is comfortable for the user. (30” - 36” recommended, 24” - 36” allowed).
b)Calculate Hood height your installation H (see Figure 2). H =
c)Confirm that H is within the range of min to max H found for your hood. If not adjust your installation.
d)Calculate Chimney structure height S (use formulas in Figure 2, and check dimensions of your hood). Save this calculation for use later in the installation.
Preparation of Mounting Surface - Installing supports above ceiling drywall.
Note: Take into consideration the hood depth; your hood could be much deeper than the cooktop.
2.Mark center lines of cooktop or range on ceiling above. Use centerlines marked on ceiling to position the mounting template. Note location of hood front, side, and mounting holes indicated on template.
3.Remove and save template. Cut and remove ceiling drywall. Install suitable length 2" x 4" lumber between joists to provide chimney mounting points as shown in Fig. C and D. Use template for dimensions and required clearance.
Make sure to affix the added lumber firmly and level. Consult a profes- sional if you have difficulties or your installation is unique. Consult template and Figures 3. 4. 5.
4.Install exhaust duct (see Table 1 for size). Female end shall be
5.Install 1/2" electrical conduit in location marked on template and extend length S from ceiling.
6.Install drywall around duct and conduit; then refinish ceiling.
5