DEAN PORTABLE MICRO-FLO OIL FILTRATION SYSTEMS

CHAPTER 3: INSTALLATION INSTRUCTIONS

3.1 Assembling The Filter System

On initial installation and before each use, remove all loose parts from the filter, wash the filter pan and all accessories in hot, soapy water and dry thoroughly.

WARNING!

Water or boil-out solution MUST not be allowed to drain into the filter pan or

filter system. Irreversible damage will result if water is allowed into the

system, and the warranty will be voided.

The MF90 filtration system uses a filter support grid, two sheets of filter paper and a hold- down ring to secure the filter paper in place.

3.1.1 Filter Paper Configuration

See illustration for proper assembly.

1.Filter Pan Cover

2.Hold-Down Ring

3.Filter Paper (2 sheets)

4.Screen/Support Grid

5.Filter Pan Assembly

5

4

3

2

1

A.First, place the support grid in the bottom of filter pan.

B.Put two filter paper sheets on top of the support grid. Be sure the paper covers the whole filter pan bottom.

C.Position the hold-down ring on top of the filter papers and latch the hold-down ring and filter papers securely against the filter pan bottom, forming a tight seal.

3-1

Page 9
Image 9
Frymaster MF90 Series manual Assembling The Filter System, Filter Paper Configuration