4.5 Unit Operation (cont.)

8.With oil return nozzle in the vessel, turn filter switch “ON” to begin pumping clean oil into the fryer. Allow the oil to recycle through the fryer for a few seconds to wash out sediment on the bottom of the cooking vessel before closing the drain valve.

9.Close the drain valve handle. It takes approximately 5 to 7 minutes for the filter to pump all the oil back into the fryer.

10.Allow the pump to run for 10-15 seconds after air starts to flow through the wand, before shutting off the filter. Clearing residual shortening/oil from the return lines reduces the likelihood of clogged lines.

CAUTION

Operating the fryer without oil in the fryer vessel will cause damage to the

fryer and the warranty will be voided.

4-7

Page 17
Image 17
Frymaster MF90 Series manual Unit Operation