TROUBLESHOOTING
WARNING | In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the electrical | |
breaker and consult authorized service personnel. | ||
| ||
| Merely turning off the unit’s power switch will not completely disconnect the unit from the power source. | |
| Always be sure to turn off the electrical breaker to ensure that power is completely off. |
Before requesting service, perform the following checks:
| Symptom | Problem | See Page |
|
|
|
|
NORMAL | Doesn’t operate | ● If the indoor unit is stopped and then immediately started again, the |
|
FUNCTION | immediately: | compressor will not operate for about 3 minutes, in order to prevent |
|
|
| fuse blowouts. | — |
|
| ● Whenever the electrical breaker is turned off then on again the pro- |
|
|
| tection circuit will operate for about 3 minutes, preventing unit opera- |
|
|
| tion during that period. |
|
|
|
|
|
| Noise is heard: | ● During operation or immediately after stopping the unit, the sound of |
|
|
| water flowing in the air conditioner’s piping may be heard. Also, noise |
|
|
| may be particularly noticeable for about 2 to 3 minutes after starting | — |
|
| operation (sound of refrigerant flowing). | |
|
| ● During operation, a slight squeaking sound may be heard. This is the |
|
|
| result of minute expansion and contraction of the front panel due to |
|
|
| temperature changes. |
|
|
|
|
|
|
| ● During Heating operation, a sizzling sound may be heard occasional. | 23 |
|
| This sound is produced by the Automatic Defrosting operation. | |
|
|
| |
|
|
|
|
| Smells: | ● Some smell may be emitted from the indoor unit. This smell is the re- | — |
|
| sult of room smells (furniture, tobacco, etc.) which have been taken | |
|
| into the indoor unit. |
|
|
|
|
|
| Mist or steam is emitted: | ● During Cooling or Dry operation, a thin mist may be seen emitted |
|
|
| from the indoor unit. This results from the sudden Cooling of room air | — |
|
| by the cool air emitted from the indoor unit, resulting in condensation | |
|
|
| |
|
| and misting. |
|
|
|
|
|
|
| ● During Heating operation, the outdoor unit’s fan may stop, and steam | 23 |
|
| may be seen rising from the unit. This is due to Automatic Defrosting | |
|
| operation. |
|
|
|
|
|
| Airflow is weak or stops: | ● When Heating operation is started, fan speed is temporarily very low, |
|
|
| to allow internal parts to warm up. |
|
|
| ● During Heating operation, if the room temperature rises above the | — |
|
| temperature setting, the outdoor unit will stop, and the indoor unit will | |
|
|
| |
|
| operate at very low fan speed. If you wish to warm the room further, |
|
|
| set the temperature for a higher setting. |
|
|
|
|
|
|
| ● During Heating operation, the indoor unit will temporarily stop opera- |
|
|
| tion (Max.15 minutes) as the Automatic Defrosting mode operates. | 23 |
|
| During Automatic Defrosting operation, the OPERATION Indicator | |
|
|
| |
|
| Lamp will flash. |
|
|
|
|
|
|
| ● During Dry mode, the indoor unit will operate at low speed; in order |
|
|
| to adjust room humidity, the indoor unit’s fan may stop from time to | 8 |
|
| time. Also, the fan may operate at very low speed when adjusting | |
|
|
| |
|
| room humidity. |
|
|
|
|
|
|
| ● During SUPER QUIET operation, the fan will operate at very low speed. | 7 |
|
|
|
|
|
| ● In the monitor of AUTO operation, the fan will operate at very low | 8 |
|
| speed. | |
|
|
| |
|
|
|
|
| Water is produced from | ● During Heating operation, water may be produced from the outdoor | 23 |
| the outdoor unit: | unit due to Automatic Defrosting operation. | |
|
| ||
|
|
|
|