Important Alert Items

Task

 

Alert message

Page

 

 

 

Maintenance

Device damage

 

 

1.

Before touching a PCA or the drive, wear a wrist strap

1-2

 

 

and perform the human body grounding to discharge

 

 

 

static electricity from your body. This will prevent

 

 

 

irreparable damage to the PCA and the head of the drive.

 

 

2.

Don’t install or remove a PCA or connect or disconnect

 

 

 

a cable or connector plug when the drive is powered.

 

 

 

This will prevent electrical damage to the disk drive.

 

 

3.

Operating the disk drive with one or more PCA missing

 

 

 

will be unpredictable. Only power the drive with all

 

 

 

boards installed.

 

 

4.

Avoid any detergent which may cause short circuits

 

 

 

when cleaning assemblies.

 

 

5.

Keep all vents open opened and unblocked. Avoid other

 

 

 

conditions which may cause circuits to overheat.

 

 

6.

A ribbon type cable has one line marked. Ensure that

 

 

 

this line is always connected to pin 1 of the cable

 

 

 

connector.

 

 

7.

Do not apply excessive force to the cover under any

 

 

 

circumstances. Doing so may cause irreparable damage

 

 

 

to the cover.

 

 

Device damage

 

 

The DE is completely sealed. Do not open the DE in the

1-3

 

field.

 

 

Data corruption

 

 

When asking for repair, save all data stored in the disk drive

1-4

 

beforehand. Fujitsu Limited is not responsible for any loss

 

 

of data during service and repair.

 

 

Device damage

 

 

The disk enclosure (DE) must never to be opened in the

1-13

 

field. Opening the disk enclosure may cause irreparable

 

 

damage.

 

 

 

 

 