12. Alarms

1.HDG SET

2.SPD MODE

3.MAN SPD

4.SET & DRIFT

5.DISPLAY

6.MARK/LINE

7.TUNE

8.NAV DATA

9.EBL/VRM/+

0.

MAN LOG NAV*

LOG (S-BT)

LOG (S-WT)

CPA/TCPA alarm

Visual and audible alarms are generated when the predicted CPA and TCPA of any target become less than their preset limits. Press the [AUDIO OFF] key to acknowledge and silence the CPA/TCPA audible alarm.

The ATA continuously monitors the predicted range at the Closest Point of Approach (CPA) and predicted time to CPA (TCPA) of each tracked target to own ship.

* NAV shown on R-type only.

Figure 9 OTHER menu

2.Press the [4] key twice to select SET/

DRIFT.

 

SET & DRIFT

1.

 

 

2.

SET/DRIFT

 

ON

OFF

3.

SET

000.0

4.

DRIFT

0-19.9 KT

Figure 10 SET/DRIFT menu

3.Press the [2] key to select ON from the SET DRIFT field, and then press the [EN- TER/SELECT] key.

4.Press the [3] key twice, enter SET value, and then press the [ENTER/SELECT] key.

5.Press the [4] key twice, enter DRIFT value, and then press the [ENTER/SE- LECT] key.

6.Press the [MENU] key.

When the predicted CPA of any target be- comes smaller than a preset CPA alarm range and its predicted TCPA less than a preset TCPA alarm limit, the ATA releases an au- dible alarm. In addition, the target plot sym- bol changes to a triangle and flashes together with its vector.

Provided that this feature is used correctly, it will help prevent the risk of collision by alert- ing you to threatening targets. It is important that GAIN, A/C SEA, A/C RAIN and other radar controls are properly adjusted and the ATA is set up so that it can track targets ef- fectively.

CPA/TCPA alarm ranges must be set up prop- erly taking into consideration the size, ton- nage, speed, turning performance and other characteristics of own ship.

The CPA/TCPA alarm feature should never be relied upon as a sole means for detecting the risk of collision. The navigator is not re- lieved of the responsibility to keep visual look- out for avoiding collisions, whether or not the radar or other plotting aid is in use.

Follow the steps shown below to set the CPA/ TCPA alarm ranges:

1.Press [MENU], [7], [7] to display PLOT MENU 1.

2.Press [5] (CPA SET) to select CPA limit desired from the CPA SET line.

3.Press the [ENTER/SELECT] key.

4.Press [6] (TCPA SET) to select a TCPA limit desired.