Target

Course

Speed

CPA*

TCPA*

 

 

 

 

 

Target 1

90.0° R

10.0 kt

1.0 nm

10.4 min

 

 

 

 

 

Target 2

0.0° R

0.0 kt

4.0 nm

 

 

 

 

 

Target 3

180.0° R

10.0 kt

1.7 nm

28.2 min

 

 

 

 

 

Target 4

216.5° R

23.8 kt

0.9 nm

15.0 min

 

 

 

 

 

Target 5

273.5° R

14.2 kt

6.0 nm

22.5 min

 

 

 

 

 

Target 6

180.0° R

20.0 kt

0.0 nm

30.0 min

 

 

 

 

 

Target 7

24.6° R

15.6 lkt

4.0 nm

43.6 min

 

 

 

 

 

* Initial data

4.The simulation continues for five minutes and then repeats. To quit the test se- quence, turn the TRACK TEST off on the PLOT MENU2.

14. Diagnostic Sequence

You can check the ATA Board for proper op- eration as follows. The self test does not re- quire operator intervention. It runs automatically when the power is placed on at regular intervals or on operator demand.

1.Press [MENU], [0], [0], [0], [0].

2.Press the [2] key twice to start the diag- nosis sequence. The results of the test appear as shown below.

FR-1500 M-3 Series Test

 

1.

Program No.

03591521**

2. ROM Check

OK

 

3. RAM Check

OK

 

4. Antenna Rotation

24RPM

 

5.

Tx Trigger Frequency 3000Hz

 

6.

Video Level

000

 

7.

Video Signal

OK

 

8.

Navigation I/O 1

OK

 

9.

Navigation I/O 2

OK

 

10. NMEA Heading IN OK

 

11. LOG Pulse IN

OK

 

ARP TEST

 

 

1.

Program No. 18590411** 18590421**

2. ROM Check

OK

OK

3. RAM Check

OK

 

4. Speed Log

OK 0.0 KT

5.

Course

OK

 

6.

Trigger

OK

 

7.

Video Signal

OK

 

8.

Bearing Pulse

OK

 

9.

Heading Pulse

OK

 

10. Minimum

0003

 

11. Scan Time

0274

 

12. Manual Acq.

00

 

13. Auto Acq.

00

 

14. FE-Data 1

0000

 

15. FE-Data 2

0000

 

Press MENU key to escape.

Press ENTER to check CRT.

** Program No.

Figure 13 Diagnostics test results

(FR-1500 MARK-3 series)

3.If NG appears for any ATA-related item, call for service.

4.To escape, press the [MENU] key.

12

Page 17
Image 17
Furuno ARP-17 manual Diagnostic Sequence, CPA Tcpa